43 / 112 page ![]() 1998 Nov 02 43 Philips Semiconductors Product specification Pager baseband controller PCA5010 SFR: • TFREQ0 to TFREQ7: 8-bit register containing the divisor of the tone. Loaded by the processor. • ENB: enable frequency generator. Control signal from processor. • CLK2: use secondary clock input for tone generation. If set a 32768 Hz clock signal is generated from the primary 76800 Hz clock signal and used as a timing reference for the tone generator. Inputs: • 76.8 kHz: Input to the tone counter. Outputs: • AT Output for alerter. Is logic 0 when disabled: 6.15.3 GENERATION OF THE 32768 HZ REFERENCE The 32768 Hz reference is generated from 76800 Hz according to the following algorithm: forever do begin for 10 times do { from 7 clocks on 76.8 kHz generate 3 pulses on 32 kHz } from 5 clocks on 76.8 kHz generate 2 pulses on 32 kHz end f AT 76.8 kHz TFREQ ----------------------- = 6.16 Watchdog timer 6.16.1 FUNCTION The watchdog timer consists of an 8-bit down counter. The binary number defined with WD3 to WD0 defines the expiration time of the watchdog timer between 1 to 16 s. Once enabled this counter is running continuously. Once expired the timer produces firstly an interrupt and finally a reset. The software must reload the watchdog in regular intervals to avoid expiration. A positive edge on the LD SFR bit (re)loads the counter with the value of WD3 to WD0, sets the LOW bits to logic 1 and activates this counter if it is not yet running. However, to prepare the (re)loading a positive edge must be applied to the COND bit in WDCON. In this way at least two locations in software must be passed before the counter can be reloaded. After reset the counter is not running. Only after the first LD it is clocked continuously by a clock pulse of 16 Hz until the DC/DC converter is switched off or an external reset is applied. If the next LD signal is not given within the defined expiry interval an overflow occurs and the processor will be reset (signal WDR). 1 clock cycle before the reset is applied an WDI interrupt is issued. This gives the opportunity to avoid the reset if required. The maximum watchdog expiry time is thus 254 × 16 Hz ticks to the WD interrupt and 255 × 16 Hz ticks to the reset. If the DC/DC converter is in the off mode, the watchdog timer is suspended. 6.16.2 WATCH DOG TIMER CONTROL REGISTER (WDCON) The WDCON special function register is used to control the operation of the on-chip watchdog timer. Table 34 Watchdog Control Register (WDCON, SFR address A5H) Table 35 Description of the WDCON bits 76543210 COND WD3 WD2 WD1 WD0 −− LD BIT SYMBOL FUNCTION WDCON.7 COND Load condition. Control signal from processor. WDCON.6 WD3 WD0 to WD3 is the preset value for the high nibble of the watchdog timer. The value is the number of seconds to expiry of the watchdog. WDCON.5 WD2 WDCON.4 WD1 WDCON.3 WD0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |