38 / 79 page ![]() Data Sheet ADF4377 APPLICATIONS INFORMATION analog.com Rev. 0 | 38 of 79 Table 33. SPI Summary - SPI Protocol Bit Field Value MAIN_READBACK_CONTROL 0x0 Remaining Register Settings The Charge Pump Test Mode section,MUXOUT section, and Block Power Down Control section list several bit fields that are rec- ommended for special purposes, such as debug or ambient die temperature measurements. For this normal use case, these bit fields must be set to their POR state (see Table 34). SOFT_RESET, SOFT_RESET_R, RST_SYS, and ADC_ST_CNV are the only re- maining RW bit fields not mentioned yet, and must also be set to their POR state (see Table 34). The bit columns in Table 42 have several cells without a name. These unnamed, reserved cells must be programmed to the state provided in Table 42 for proper operation. Table 34. SPI Summary, Remaining Registers Bit Field Value EN_CPTEST 0x0 CP_UP 0x0 CP_DOWN 0x0 MUXOUT 0x0 PD_CLK 0x0 PD_CALDAC 0x0 PD_ALL 0x0 PD_RDIV 0x0 PD_NDIV 0x0 PD_VCO 0x0 PD_LD 0x0 PD_PFDCP 0x0 SOFT_RESET, SOFT_RESET_R 0x0 RESET_SYS 0x0 ADC_ST_CNV 0x0 Programming Procedure There are two different methods to power up the ADF4377. The most commonly used method provided in the Standard Power-Up and Initialization Sequence, Automatic VCO Calibration section is mandatory on the initial device power-up. The method provided in the Fast Power-Up and Initialization, Man- ually Programmed VCO Calibration Settings (Optional) section is an optional power-up procedure after the initial power-up. Standard Power-Up and Initialization Sequence, Automatic VCO Calibration The following standard power-up and initialization sequence is the recommended procedure to power up and program the ADF4377: 1. Follow Step 1 through Step 5 in the Power-Up and Initialization Sequence section, using the register settings provided in the Design Procedure section. 2. It is optional to monitor the status of the VCO calibration bit fields, ADC_BUSY and FSM_BUSY. A VCO calibration is com- pleted when ADC_BUSY transitions from high to low, followed by FSM_BUSY transitioning from high to low. Typical automatic VCO calibration times range from 3 ms to 9 ms. 3. After the VCO calibration is complete, disable the VCO calibration clocks by setting EN_DRCLK = EN_DNCLK = EN_ADC_CLK = 0. Disabling the VCO calibration clocks re- duces the V3.3V_1 current by roughly 15 mA and reduces unwanted spurious content. 4. PLL is locked when the lock detector sets the LKDET pin and the LOCKED bit high. Fast Power-Up and Initialization, Manually Programmed VCO Calibration Settings (Optional) The purpose of the fast power-up and initialization method is to avoid the automatic VCO calibration time, which is typically 3 ms to 9 ms. For fixed clock frequency converter applications, such as this design and programming Example 1, automatic VCO calibration times are typically acceptable. The following list provides the steps to record the VCO calibration results on the initial power-up and manually program VCO Calibration settings on subsequent power ups: 1. On initial power, follow the procedure in the Standard Power-Up and Initialization Sequence, Automatic VCO Calibration section. 2. Record calibration results from the VCO_CORE, VCO_BAND, and VCO_BIAS bit fields and store the recorded results in memory. Note that each unique device and frequency com- bination generates different VCO_CORE, VCO_BAND, and VCO_BIAS values. 3. Subsequent power-up and initialization sequences (see the- Power-Up and Initialization Sequence section) can bypass the automatic VCO calibration procedure by programming the over- ride (O_VCO_CORE, O_VCO_BAND, and O_VCO_BIAS) and manual (M_VCO_CORE, M_VCO_BAND, and M_VCO_BIAS) VCO register bits with the register settings provided in Table 35. All other bit fields from the Design Procedure section remain the same. Table 35. Manually Programmed VCO Calibration Settings Bit Fields Value EN_AUTOCAL 0x0 EN_DRCLK 0x0 EN_DNCLK 0x0 EN_ADC_CLK 0x0 O_VCO_CORE 0x1 O_VCO_BAND 0x1 O_VCO_BIAS 0x1 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |