| поискавой системы для электроныых деталей |
|
CS48L32 датащи(PDF) 90 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS48L32 датащи(HTML) 90 Page - Cirrus Logic |
|
90 / 192 page ![]() 90 Cirrus Logic DS1219F4 CS48L32 4.5 DSP Peripheral Control If SYSCLK is selected as the source, a lower clocking frequency can be configured using TIMERn_REFCLK_FREQ_SEL field (if TIMERn_REFCLK_SRC = 0x8) or TIMERn_DSPCLK_FREQ_SEL field (if TIMERn_REFCLK_SRC = 0x0). The applicable division ratio is determined automatically, assuming the SYSCLK frequency has been correctly configured as described in Section 4.8. Note that, depending on the SYSCLK frequency and the available clock dividers, the timer reference frequency may differ from the frequency configured by TIMERn_DSPCLK_FREQ_SEL. In most cases, the timer reference equals or exceeds the requested frequency; a lower frequency is implemented if limited by either the SYSCLK frequency or the maximum TIMERn clocking frequency. If TIMERn_REFCLK_SRC > 0x0, the clock source can be further divided using TIMERn_REFCLK_DIV. Division ratios in the range 1 to 128 can be selected. The reference frequency (after TIMERn_REFCLK_FREQ_SEL, TIMERn_DSPCLK_FREQ_SEL, and TIMERn_REFCLK_ DIV) must be compatible with the following constraints: • The reference frequency must be less than 12 MHz, and close to 50% duty cycle • If SYSCLK is enabled, the reference frequency must be less than SYSCLK / 3 One final division, controlled by TIMERn_PRESCALE, determines the timer count frequency. This field is valid for all clock reference sources; division ratios in the range 1 to 128 can be selected. The output from this division corresponds to the frequency at which the TIMERn_COUNT field is incremented (or decremented). The maximum count value of the timer is determined by TIMERn_MAX_COUNT. This is the final count value (if counting up), or the initial count value (if counting down). The current value of the timer counter can be read from the TIMERn_ CUR_COUNT field. The timer is started by writing 1 to TIMERn_START. Note that, if the timer is already running, it restarts from its initial value. The timer is stopped by writing 1 to TIMERn_STOP. The count direction (up or down) is selected using TIMERn_DIR. The TIMERn_CONT bit selects whether the timer automatically restarts after the end-of-count condition has been reached. The TIMERn_RUNNING_STS bit indicates whether the timer is running, or if it has stopped. Note that the timer should be stopped before making any changes to the timer control registers. The timer configuration should only be changed if TIMERn_RUNNING_STS = 0. 4.5.3.3 Interrupts and GPIO Output The timer status is an input to the interrupt control circuit and can be used to trigger an interrupt event after the final count value is reached—see Section 4.9. Note that the interrupt does not occur immediately when the final count value is reached; the interrupt is triggered at the point when the next update to the timer count value would be due. The timer status can be output directly on a GPIO pin as an external indication of the timer activity. See Section 4.10 to configure a GPIO pin for this function. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |