| поискавой системы для электроныых деталей |
|
L9966 датащи(PDF) 36 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9966 датащи(HTML) 36 Page - STMicroelectronics |
|
36 / 122 page ![]() 8.2 ADC2: resistance measurement The device implements a dedicated function to perform high precision resistance measurements connected between analog input pin IO[12:1] and ground. In Figure 17 a simplified circuit is reported.. Figure 17. Simplified circuit for resistance measurement GADG0801180852PS A wide measurement range is allowed by selecting the pull-up external reference resistors. Digital out is RPD/RRx represented over 15 bits fixed point number (4 bits integer, 11 bits fractional). The result from the SPI register needs then to be divided by 2048. RPD=ADC2_RESULT 2048 *RRx In order to reach the best accuracy, calibration of ADC, both ADC1 and ADC2, has to be activated by setting CALIB_SEL to ‘1’. Calibration feature is guaranteed in case calibration fault CALIB_FLT flag in GEN_STATUS register is not set. By default the calibration is disabled (CALIB_SEL = ‘0’): the status of the CALIB_FLT flag should be verified, then the calibration eventually enabled or kept disabled accordingly. Depending on the selected external pull-up resistance RRx, a specific settling time has to be considered (see Table 23. ADC2 parameters). Bit CT_PUx[3:0] in ADC_TIMING register can be used to set the proper settling time for each pull up resistance selected (RRx). Best accuracy is achieved when RPD/RRx is close to 1. Table 23. ADC2 parameters Symbol Parameter Condition Min Typ Max Unit UBSW = 7.5 V:36 V, VDD5V = 4.85 V:5.15 V, Tj-max = 150 °C unless otherwise specified. RMEASrange Resistance measurement range - 50 400K Ω RMEASacc_L Total resistance measurement accuracy 0.1<RPD/RRx<8 50 to 2K, RRx = 470 Ω Excl. external pull-up RRx precision No ratiometric comparator running CALIB_FLT=0 and CALIB_SEL=1 - - 1.5 % RMEASacc_M Total resistance measurement accuracy 0.1<RPD/RRx<8 2K to 30K, RRx = 9 kΩ Excl. external pull-up RRx precision No ratiometric comparator running CALIB_FLT=0 and CALIB_SEL=1 - - 1.5 % L9966 ADC2: resistance measurement DS12459 - Rev 10 page 36/122 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |