82 / 113 page ![]() NXP Semiconductors FS5502 High voltage PMIC with multiple SMPS and LDO 22 Electrostatic discharge 22.1 Human body model (JESD22/A114) The device is protected up to ±2 kV, according to the human body model standard with 100 pF and 1.5 kΩ. This protection is ensured at all pins. 22.2 Charged device model • The device is protected up to ±500 V, according to AEC-Q100 - 011 charged device model standard. This protection is ensured at all pins. 22.3 Discharged contact test The device is protected up to ±8 kV, according to the following discharged contact tests. Discharged contact test (IEC61000-4-2) at 150 pF and 330 Ω Discharged contact test (ISO10605.2008) at 150 pF and 2 kΩ Discharged contact test (ISO10605.2008) at 330 pF and 2 kΩ This protection is ensured at VSUP1, VSUP2, WAKE1, WAKE2 pins. 23 Operating conditions aaa-030983 NO OPERATION NO OPERATION RISK OF DAMAGE VSUP1/2 60 V EXTENDED OPERATION FULL OPERATION EXTENDED OPERATION 36 V VSUP_UVH 5.1 V LPI_DCR x IPRE + VPRE_UVL/DMAX Assumptions LPI_DCR = 30 mΩ DMAX = 98.18 % with FPRE_SW = 455 kHz and TPRE_OFF_MIN = 40 ns IPRE = 3.0 A VRBD = 0.56 V VBAT_MIN = 3.4 V when VPRE = VPRE_UVL Figure 29. Operating range • Below VSUP_UVH threshold, the extended operation range depends on VPRE output voltage configuration and external components. – When VPRE is configured at 5.0 V, VPRE may not remain in its regulation range – VSUP minimum voltage depends on external components (LPI_DCR) and application conditions (IPRE, FPRE_SW) • The FS5502 maximum continuous operating voltage is 36 V when VPRE is switching at 455 kHz. • The FS5502 maximum continuous operating voltage is 36 V when VPRE is switching at 455 kHz. It has been validated at 48 V for limited duration of 15 minutes at room temperature to satisfy the jump-start requirement of 24 V applications. It can sustain 58 V load dump without external protection. • When VPRE is switching at 2.2 MHz, the FS5502 maximum continuous operating voltage is 18 V. It is validated at 26 V for limited duration of 2 minutes at room FS5502 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2021. All rights reserved. Product data sheet Rev. 4 — 27 October 2021 82 / 113 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |