26 / 39 page ![]() ADF4401A Data Sheet Rev. 0 | Page 26 of 39 Address: 0x1A, Default: 0x03, Name: REG001A 14-Bit MOD2 Value. 0 1 1 1 2 0 3 0 4 0 5 0 6 0 7 0 [7:6] RESERVED [5:0] MOD2WORD[13:8] (R/W) Table 20. Bit Descriptions for REG001A Bit(s) Bit Name Description Default Access [7:6] RESERVED Reserved. 0x0 R [5:0] MOD2WORD[13:8] 14-Bit MOD2 Value. Sets the MOD2 value. 0x3 R/W Address: 0x1E, Default: 0x48, Name: REG001E Charge Pum p Current Setting. Counter Res et. Internal Phas e Detector Polarity. Power-Down. 0 0 1 0 2 0 3 1 4 0 5 0 6 1 7 0 [7:4] CP_CURRENT (R/W) [0] CNTR_RESET (R/W) [3] PD_POL (R/W) [1] RESERVED [2] PD (R/W) Table 21. Bit Descriptions for REG001E Bit(s) Bit Name Description Default Access [7:4] CP_CURRENT Charge Pump Current Setting. Sets the charge pump current. Set the CP_CURRENT bits to the charge pump current that the loop filter is designed for. 0x4 R/W 0: 0.35 mA. 1: 0.70 mA. 10: 1.05 mA. 11: 1.4 mA. 100: 1.75 mA. 101: 2.1 mA. 110: 2.45 mA. 111: 2.8 mA. 1000: 3.15 mA. 1001: 3.5 mA. 1010: 3.85 mA. 1011: 4.2 mA. 1100: 4.55 mA. 1101: 4.9 mA. 1110: 5.25 mA. 1111: 5.6 mA. 3 PD_POL Internal Phase Detector Polarity. If using a noninverting loop filter, set phase detector polarity to positive. If using an inverting loop filter, set phase detector polarity to negative. 0x1 R/W 0: negative phase detector polarity. 1: positive phase detector polarity. 2 PD Power-Down. Setting to 1 powers down all internal PLL blocks of the VCO/PLL. The VCO and multipliers remain powered up. The registers do not lose their values. After bringing the ADF4401A back to calibration mode (setting to 0) a write to REG0010 is required to relock the calibration loop. 0x0 R/W 0: calibration mode. 1: translation loop mode. 1 RESERVED Reserved. 0x0 R 0 CNTR_RESET Counter Reset. Setting to 1 holds the N divider and R counter in reset. There are no signals entering the PFD. 0x0 R/W 0: normal operation. 1: counter reset. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |