| поискавой системы для электроныых деталей |
|
WM8912 датащи(PDF) 126 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
WM8912 датащи(HTML) 126 Page - Cirrus Logic |
|
126 / 129 page ![]() WM8912 Production Data w PD, Rev 4.1, February 2013 126 APPLICATIONS INFORMATION RECOMMENDED EXTERNAL COMPONENTS Figure 56 Recommended External Components Notes: 1. Decoupling Capacitors X5R ceramic capacitor is recommended for capacitors C7, C8, C13, C14, C15, C17 and C18. The positioning of C7 is very important - this should be as close to the WM8912 as possible. Capacitors C17 and C18 should also be positioned as close to the WM8912 as possible. 2. Charge Pump Capacitors Specific recommendations for C12, C17 and C18 are provided in Table 66. Note that two different recommendations are provided for C17 and C18; either of these components is suitable, depending upon size requirements and availability. The positioning of C12 is very important - this should be as close to the WM8912 as possible. It is important to select a suitable capacitor type for the Charge Pump. Note that the capacitance may vary with DC voltage; care is required to ensure that required capacitance is achieved at the applicable operating voltage, as specified in Table 66. The capacitor datasheet should be consulted for this information. COMPONENT REQUIRED CAPACITANCE VALUE PART NUMBER VOLTAGE TYPE SIZE C12 (CPCA-CPCB) 1F at 2VDC 2.2 F Kemet C0402C225M9PAC 6.3v X5R 0402 C17 (CPVOUTP) C18 (CPVOUTN) 2F at 2VDC 2.2 F MuRata GRM188R61A225KE34D 10v X5R 0603 4.7 F MuRata GRM155R60J475M_EIA 6.3v X5R 0402 Table 66 Charge Pump Capacitors 3. ZOBEL NETWORKS The Zobel network shown in Figure 56 is required on HPOUTL, HPOUTR, LINEOUTL and LINEOUTR whenever that output is enabled. Stability of these ground-referenced outputs across all process corners cannot be guaranteed without the Zobel network components. (Note that, if any ground-referenced output pin is not required, the zobel network components can be omitted from the output pin, and the pin can be left floating.) The Zobel network requirement is detailed further in the applications note WAN_0212 “Class W Headphone Impedance Compensation”. Zobel networks (C9, C10, C11, C16, R3, R4, R5, R6) should be positioned reasonably close to the WM8912. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |