| поискавой системы для электроныых деталей |
|
WM8912 датащи(PDF) 71 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
WM8912 датащи(HTML) 71 Page - Cirrus Logic |
|
71 / 129 page ![]() Production Data WM8912 w PD, Rev 4.1, February 2013 71 In order to follow the above requirements for FVCO, the value of FLL_OUTDIV should be selected according to the desired output FOUT. The divider, FLL_OUTDIV, must be set so that FVCO is in the range 90-100MHz. The available divisions are integers from 4 to 64. Some typical settings of FLL_OUTDIV are noted in Table 46. OUTPUT FREQUENCY FOUT FLL_OUTDIV 2.8125 MHz - 3.125 MHz 011111 (divide by 32) 3.75 MHz - 4.1667 MHz 011000 (divide by 24) 5.625 MHz - 6.25 MHz 001111 (divide by 16) 11.25 MHz - 12.5 MHz 000111 (divide by 8) 18 MHz - 20 MHz 000100 (divide by 5) 22.5 MHz - 25 MHz 000011 (divide by 4) Table 46 Selection of FLL_OUTDIV The value of FLL_FRATIO should be selected as described in Table 47. REFERENCE FREQUENCY FREF FLL_FRATIO 1MHz - 13.5MHz 0h (divide by 1) 256kHz - 1MHz 1h (divide by 2) 128kHz - 256kHz 2h (divide by 4) 64kHz - 128kHz 3h (divide by 8) Less than 64kHz 4h (divide by 16) Table 47 Selection of FLL_FRATIO In order to determine the remaining FLL parameters, the FLL operating frequency, FVCO, must be calculated, as given by the following equation: FVCO = (FOUT x FLL_OUTDIV) The value of FLL_N and FLL_K can then be determined as follows: N.K = FVCO / (FLL_FRATIO x FREF) See Table 48 for the coding of the FLL_OUTDIV and FLL_FRATIO fields. Note that FREF is the input frequency, after division by FLL_CLK_REF_DIV, where applicable. In FLL Fractional Mode, the fractional portion of the N.K multiplier is held in the FLL_K register field. This field is coded as a fixed point quantity, where the MSB has a weighting of 0.5. Note that, if desired, the value of this field may be calculated by multiplying K by 2 16 and treating FLL_K as an integer value, as illustrated in the following example: If N.K = 8.192, then K = 0.192 Multiplying K by 2 16 gives 0.192 x 65536 = 12582.912 (decimal) Apply rounding to the nearest integer = 12583 (decimal) = 3127 (hex) For best performance, FLL Fractional Mode should always be used. Therefore, if the calculations yield an integer value of N.K, then it is recommended to adjust FLL_OUTDIV in order to obtain a non- integer value of N.K. Care must always be taken to ensure that the FLL operating frequency, FVCO, is within its recommended limits of 90-100 MHz. The register fields that control the FLL are described in Table 48. Example settings for a variety of reference frequencies and output frequencies are shown in Table 50. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |