52 / 108 page ![]() Data Sheet ADE9078 Rev. 0 | Page 51 of 107 Functions Using Zero Crossing ZX Transitions Used Corresponding STATUS1 Bits Selecting Which Phase to Use for Measurement Effect if ZX Does Not Occur Resampling None Not applicable LP_SEL selects the phase voltage line period used as the basis for resampling calculation If the line period used for resampling is invalid because zero crossings are not detected or the calculation results in something outside a 40 Hz to 70 Hz range, the line period used for resampling is coerced to the default line period of 0x00500000 if SELFREQ = 0 for a 50 Hz network, or 0x0042AAAB if SELFREQ = 1 for a 60 Hz network. Angle Measurements Negative to positive Not applicable Not applicable The register does not update, keeps last value. ZX Output on the CF3/ZX Pin Negative to positive and positive to negative Not applicable ZX_SEL selects the zero- crossing output used for line cycle energy accumulation and the ZX output pin The ZX output remains at the current state, high or low. Zero-Crossing Timeout The zero-crossing timeout feature alerts the user if a zero-crossing event is not generated after a user configured amount of time. If a zero crossing event is not received after ZXTOUT/4 kSPS clocks, the corresponding ZXTOx bit in the STATUS1 register is set. For example, if ZXTOUT is equal to 4000, if a zero crossing is not received on Phase A for 4000/4 kSPS = 1 sec, the ZXTOA bit is set in the STATUS1 register. The maximum value that can be written to the ZXTOUT register is 0xFFFF/4000 = 16.38 sec. Line Period Calculation The ADE9078 line period measurement is performed by taking the values low-pass filtered by LPF1 as described in the Zero- Crossing Detection section and then using the two values near the negative to positive zero crossing (POS1 and POS2) to calculate the exact zero-crossing point using linear interpolation. Use this information to calculate the line period precisely, which is stored in the xPERIOD register. 4.3ms AT 50Hz Ix,Vx 0.86 0V LPF1 OUTPUT POS2 POS1 POS2 x x x x POS1 Figure 73. Line Period Calculation Using Zero-Crossing Detection and Linear Interpolation The line period, tL, can be calculated from the xPERIOD register, according to the following equation: (sec) 2 4000 1 16 xPERIOD t L Similarly, the line frequency can be calculated from the xPERIOD register using the following equation: (Hz) 1 2 4000 16 xPERIOD f L With a 50 Hz input, the xPERIOD register is 0x0050 0000, 5242880d, and with a 60 Hz input, it is 0x0042 AAAA = 4369066d. If the calculated period value is outside the range of 40 Hz to 70 Hz, or if the negative to positive zero crossings for that phase are not detected, the xPERIOD register is coerced to correspond to 50 Hz or 60 Hz, according to the setting of the SELFREQ bit in the ACCMODE register. With SELFREQ = 0 for a 50 Hz network, xPERIOD register is coerced to 0x0050 0000. If SELFREQ = 1, indicating a 60 Hz network, the xPERIOD register is coerced to 0x0042 AAAA. The line period is calculated for the Phase A, Phase B, and Phase C voltages and the combined voltage signal, as described in the Combined Voltage Zero Crossing section, and stored in the APERIOD, BPERIOD, CPERIOD, and COM_PERIOD, registers respectively. Select the phase voltage line period to use as the basis for the resampling calculation using the LP_SEL bits in the ZX_LP_SEL register or select a user configured value written in USER_PERIOD using the UPERIOD_SEL bit in the CONFIG2 register, as shown in Figure 74. LP_SEL 11 COM_PERIOD CPERIOD BPERIOD APERIOD RESAMPLING1 1NOT AVAILABLE IN ADE9078 PSM1. USER_PERIOD UPERIOD_SEL WAVEFORM BUFFER1 SINC4 OUTPUT SINC4 + IIR LPF OUTPUT xI_PCF, xV_PCF ADE9078 WF_CAP_SEL WF_SRC 10 01 00 Figure 74. Line Period Selection for Resampling The user period selection is helpful in applications where the user has another algorithm to determine the line frequency or if it is preferred to always assume a certain line frequency when resampling. USER_PERIOD[31:0] has the same scaling as the xPERIOD registers. Write USER_PERIOD[31:0] to 0x00500000 for 50 Hz and 0x0042AAAB for 60 Hz. Angle Measurement The ADE9078 measures the time between zero crossings on each phase. This measurement determines if the system is balanced properly or to determine if there was an installation |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |