| поискавой системы для электроныых деталей |
|
ADE9078ACPZ датащи(PDF) 51 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE9078ACPZ датащи(HTML) 51 Page - Analog Devices |
|
51 / 108 page ![]() ADE9078 Data Sheet Rev. 0 | Page 50 of 107 HPF ZX DETECTION, LINE PERIOD CALCULATION LPF1 PHASE COMP HPFDIS HPFDIS HPFDIS ZX_SRC_SEL AV_PCF PHASE A PHASE B PHASE C (VA + VB – VC)/2 HPF ZX_SRC_SEL BV_PCF HPF PHASE COMP ZX_SRC_SEL CV_PCF ÷ 2 VCONSEL[2:0] 0 PHASE COMP Figure 71. Combined Zero-Crossing Detection xx_PCF LPF1 ZX_SRC_SEL ZX DETECTION ANGLE MEASUREMENT ZX OUTPUT ON CF3/ZX PIN fDSP CLKIN/24UPDATE ÷32 ZX INDICATION IN STATUS1 ZERO-CROSSING TIMEOUT PHASE SEQUENCE ERROR DETECTION RESAMPLING, ENERGY ACCUMULATION LINE PERIOD Figure 72. Zero-Crossing Output Rates Table 21. Zero Crossing Use in Other Functions Functions Using Zero Crossing ZX Transitions Used Corresponding STATUS1 Bits Selecting Which Phase to Use for Measurement Effect if ZX Does Not Occur ZX Indication in STATUS1 Register Negative to positive and positive to negative ZXIA, ZXIB, ZXIC, ZXVA, ZXVB, ZXVC, and ZXCOMB Not applicable The ZXx bit is latched in STATUS1. If it is cleared, it is not set again. A ZXx interrupt does not occur. Zero-Crossing Timeout Negative to positive and positive to negative ZXTOVA, ZXTOVB, and ZXTOVC Not applicable Zero-crossing timeout is indicated by the ZXTOVx bits in the STATUS1 register and an interrupt can be enabled to occur. Phase Sequence Error Detection Depends on VCONSEL setting SEQERR Not applicable If one to two ZX events are missing, SEQERR is generated. If all ZX events are missing, the SEQERR bit is not set. Energy Accumulation Negative to positive and positive to negative Not applicable ZX_SEL selects the zero- crossing output used for line cycle energy accumulation and ZX output pin Line cycle accumulation does not update. Line Period Measurement Negative to positive Not applicable One line period measurement per phase (APERIOD, BPERIOD, CPERIOD, COMPERIOD) Coerced to default value of 0x00500000 if SELFREQ = 0 for a 50 Hz network or 0x0042AAAB if SELFREQ = 1 for a 60 Hz network. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |