| поискавой системы для электроныых деталей |
|
TDA8029HL/C2 датащи(PDF) 18 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDA8029HL/C2 датащи(HTML) 18 Page - NXP Semiconductors |
|
18 / 58 page ![]() 2003 Oct 30 18 Philips Semiconductors Product specification Low power single card reader TDA8029 8.2.5 TIMER/COUNTER 2 SET-UP Except for the baud rate generator mode, the values given for T2CON do not include the setting of the TR2 bit. Therefore, bit TR2 must be set, separately, to turn the timer on. Table 10 Timer 2 as a timer Notes 1. Capture/reload occurs only on timer/counter overflow. 2. Capture/reload on timer/counter overflow and a HIGH to LOW transition on T2EX, except when timer 2 is used in the baud rate generator mode. Table 11 Timer 2 as a counter Notes 1. Capture/reload occurs only on timer/counter overflow. 2. Capture/reload on timer/counter overflow and a HIGH to LOW transition on T2EX (P1.1) pin except when timer 2 is used in the baud rate generator mode. 8.3 Enhanced UART The UART operates in all of the usual modes that are described in the first section of “ Data Handbook IC20, 80C51-based 8-bit microcontrollers”. In addition the UART can perform framing error detection by looking for missing stop bits and automatic address recognition. The UART also fully supports multiprocessor communication as does the standard 80C51 UART. When used for framing error detection the UART looks for missing stop bits in the communication. A missing bit will set the bit FE or bit 7 in the SCON register. Bit FE is shared with bit SM0. The function of SCON bit 7 is determined by bit 6 in register PCON (bit SMOD0). If SMOD0 is set then bit 7 of register SCON functions as FE and as SM0 when SMOD0 is cleared. When used as FE this bit can only be cleared by software. 8.3.1 SERIAL PORT CONTROL REGISTER (SCON) Table 12 Serial port control register bits MODE T2CON INTERNAL CONTROL(1) (HEX) EXTERNAL CONTROL(2) (HEX) 16-bit auto-reload 00 08 Baud rate generator receive and transmit same baud rate 34 36 Receive only 24 26 Transmit only 14 16 MODE T2CON INTERNAL CONTROL(1) (HEX) EXTERNAL CONTROL(2) (HEX) 16-bit 02 04 Auto-reload 03 0B BIT 7 6 543210 Symbol SM0/FE SM1 SM2 REN TB8 RB8 TI RI |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |