| поискавой системы для электроныых деталей |
|
OR2C04A датащи(PDF) 19 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
OR2C04A датащи(HTML) 19 Page - List of Unclassifed Manufacturers |
|
19 / 192 page ![]() Lucent Technologies Inc. 19 Data Sheet June 1999 ORCA Series 2 FPGAs Programmable Logic Cells (continued) Inter-PLC Routing Resources The inter-PLC routing is used to route signals between PLCs. The lines occur in groups of four, and differ in the numbers of PLCs spanned. The X1 lines span one PLC, the X4 lines span four PLCs, the XH lines span one-half the width (height) of the PLC array, and the XL lines span the width (height) of the PLC array. All types of lines run in both horizontal and vertical directions. Table 5 shows the groups of inter-PLC lines in each PLC. In the table, there are two rows/columns each for X1 and X4 lines. In the design editor, the horizontal X1 and X4 lines are located above and below the PFU. Similarly, the vertical segments are located on each side. The XL and XH lines only run below and to the left of the PFU. The indexes specify individual lines within a group. For example, the VX4[2] line runs vertically to the left of the PFU, spans four PLCs, and is the third line in the 4-bit wide bus. Table 5. Inter-PLC Routing Resources Figure 21 shows the inter-PLC routing within one PLC. Figure 22 provides a global view of inter-PLC routing resources across multiple PLCs. 5-4528(F) Figure 21. Single PLC View of Inter-PLC Lines X1 Lines. There are a total of 16 X1 lines per PLC: eight vertical and eight horizontal. Each of these is sub- divided into nibble-wide buses: HX1[3:0], HX1[7:4], VX1[3:0], and VX1[7:4]. An X1 line is one PLC long. If a net is longer than one PLC, an X1 line can be lengthened to n times its length by turning on n – 1 CIPs. A signal is routed onto an X1 line via the switch- ing lines. X4 Lines. There are four sets of four X4 lines, for a total of 16 X4 lines per PLC. They are HX4[3:0], HX4[7:4], VX4[3:0], and VX4[7:4]. Each set of X4 lines is twisted each time it passes through a PLC, and one of the four is broken with a CIP. This allows a signal to be routed for a length of four cells in any direction on a single line without additional CIPs. The X4 lines can be used to route any nets that require minimum delay. A longer net is routed by connecting two X4 lines together by a CIP. The X4 lines are accessed via the switching lines. Horizontal Lines Vertical Lines Distance Spanned HX1[3:0] VX1[3:0] One PLC HX1[7:4] VX1[7:4] One PLC HX4[3:0] VX4[3:0] Four PLCs HX4[7:4] VX4[7:4] Four PLCs HXL[3:0] VXL[3:0] PLC Array HXH[3:0] VXH[3:0] 1/2 PLC Array CKL, CKR CKT, CKB PLC Array PROGRAMMABLE FUNCTION UNIT DIRECT[4:0] HX4[7:4] HX1[7:4] DIRECT[4:0] HXH[3:0] HX1[3:0] DIRECT[4:0] DIRECT[4:0] HX4[3:0] HXL[3:0] CKL, CKR |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |