| поискавой системы для электроныых деталей |
|
OR2C04A датащи(PDF) 57 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
OR2C04A датащи(HTML) 57 Page - List of Unclassifed Manufacturers |
|
57 / 192 page ![]() Lucent Technologies Inc. 57 Data Sheet June 1999 ORCA Series 2 FPGAs Special Function Blocks (continued) ORCA Series TAP Controller (TAPC) The ORCA Series TAP controller (TAPC) is a 1149.1 compatible test access port controller. The 16 JTAG state assignments from the IEEE 1149.1 specification are used. The TAPC is controlled by TCK and TMS. The TAPC states are used for loading the IR to allow three basic functions in testing: providing test stimuli (Update-DR), test execution (Run-Test/Idle), and obtaining test responses (Capture-DR). The TAPC allows the test host to shift in and out both instructions and test data/results. The inputs and outputs of the TAPC are provided in the table below. The outputs are primarily the control signals to the instruction register and the data register. Table 13. TAP Controller Input/Outputs The TAPC generates control signals which allow cap- ture, shift, and update operations on the instruction and data registers. In the capture operation, data is loaded into the register. In the shift operation, the captured data is shifted out while new data is shifted in. In the update operation, either the instruction register is loaded for instruction decode, or the boundary-scan register is updated for control of outputs. The test host generates a test by providing input into the ORCA Series TMS input synchronous with TCK. This sequences the TAPC through states in order to perform the desired function on the instruction register or a data register. Figure 50 provides a diagram of the state transitions for the TAPC. The next state is deter- mined by the TMS input value. 5-5370(F) Figure 50. TAP Controller State Transition Diagram Symbol I/O Function TMS I Test Mode Select TCK I Test Clock PUR I Powerup Reset PRGM I BSCAN Reset TRESET O Test Logic Reset Select O Select IR (high); Select DR (low) Enable O Test Data Out Enable Capture-DR O Capture/Parallel Load DR Capture-IR O Capture/Parallel Load IR Shift-DR O Shift Data Register Shift-DR O Shift Instruction Register Update-DR O Update/Parallel Load DR Update-IR O Update/Parallel Load IR SELECT- DR-SCAN CAPTURE-DR SHIFT-DR EXIT1-DR PAUSE-DR EXIT2-DR UPDATE-DR 1 1 0 0 10 RUN-TEST/ IDLE 1 TEST-LOGIC- RESET SELECT- IR-SCAN CAPTURE-IR SHIFT-IR EXIT1-IR PAUSE-IR EXIT2-IR UPDATE-IR 1 1 0 10 00 0 0 1 0 1 1 1 0 1 1 0 0 0 0 1 11 0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |