| поискавой системы для электроныых деталей |
|
MPF0900AMMA2ES датащи(PDF) 50 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF0900AMMA2ES датащи(HTML) 50 Page - NXP Semiconductors |
|
50 / 205 page ![]() NXP Semiconductors PF09 Nine-channel power management IC with advanced system safety monitoring If a switching regulator is programmed to turn off upon an OV or UV fault ant the SWx_FLT_REN = 1, the switching regulator will be re-enabled 500 μs after the regulator output has finished its discharge cycle. If an LDO regulator is programmed to turn off upon an OV or UV fault and the LDOx_FLT_REN = 1, the LDO regulator will allow up to 1000 μs to discharge the output before trying to turn the LDO back on. If an LDO or switching regulator is programmed to turn off upon an OV or UV fault and the _FLT_REN bit is set to 0, the regulator will remain disabled and the MCU can turn it back on by toggling off and on the corresponding enable/mode bits. The _FLT_REN bits are defaulted to 1 at power-up, and the MCU is expected to configure the desired behavior for each voltage regulator during the system configuration sequence during the booting stage. 12.6.2.2 Fault bypass control The PF09 provides a set of fault bypass configuration bits to assign different levels of priority to each specific fault for each voltage regulator and external voltage monitor. The system LDOs and switching regulators are provided with an _IL_BYP bit to bypass the ILIM protection mechanisms. By default, the _IL_BYP bits are set to 1 and the MCU is expected to set the desired configuration during the system configuration sequence at power-up. SWx_IL_BYP LDOx_IL_BYP ILIM protection 0 Enabled 1 Bypassed Table 47. ILIM protection bypass bit The System LDOs and switching regulators are provided with an _OV_BYP bits to bypass the OV protection mechanism on the respective block. By default the _OV_BYP bits are set to 0 and the MCU is expected to set the desired configuration during the system configuration sequence at power-up. SWx_OV_BYP LDOx_OV_BYP OV protection 0 Enabled 1 Bypassed Table 48. OV protection bypass bit The System LDOs and switching regulators are provided with an _UV_BYP bits to bypass the UV protection mechanism on the respective block. By default the _UV_BYP bits are set to 0 and the MCU is expected to set the desired configuration during the system configuration sequence at power-up. SWx_UV_BYP LDOx_UV_BYP UV protection 0 Enabled 1 Bypassed Table 49. UV protection bypass bit The table below lists all the functional bits associated with enabling/disabling the voltage regulators when they experience an OV/UV condition. Regulator bit to bypass a current limit bit to bypass an undervoltage bit to bypass an overvoltage SW1 SW1_IL_BYP SW1_UV_BYP SW1_OV_BYP SW2 SW2_IL_BYP SW2_UV_BYP SW2_OV_BYP Table 50. Bits to enable/disable regulators at UV/OV PF09 All information provided in this document is subject to legal disclaimers. © 2026 NXP B.V. All rights reserved. Product data sheet Rev. 1.3 — 16 December 2025 Document feedback 50 / 205 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |