Back Button MPF0900AMMA2ES Datasheet HTML 19Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 20Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 21Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 22Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 23Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 24Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 25Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 26Page - NXP Semiconductors MPF0900AMMA2ES Datasheet HTML 27Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 205 page
background image
NXP Semiconductors
PF09
Nine-channel power management IC with advanced system safety monitoring
When the device transitions from the RUN to the STANDBY state, the system will trigger a PWRDN_I interrupt.
The PWRDN_I event will assert the INTB pin only if the PWRDN_M = 0 (interrupt un-masked). By default, the
PWRDN_M bit is masked upon power up.
11.2.9 Power-down sequence
Three types of events may lead to the power-down sequence.
• Non-faulty or requested turn-off event
• Turn-off events due to a PMIC fault
• Reset event
During the power-down sequence, the system regulators are disabled as described in the power-down
sequencing section.
11.2.9.1 TURNOFF state
Non-faulty turn-off events move directly into the corresponding low-power state as soon as the power-down
sequence is finalized.
If the VAON is set to operate as an always-on regulator, the VAON output will remain enabled during the turn-
off event and into the low-power modes. If the VAON is set as a system regulator, the VAON regulator will be
disabled as defined in the power-down sequence.
All other system regulators will be disabled as defined in the power-down sequence.
11.2.9.2 FAULT state
Turn-off events due to a PMIC fault will move into the Fail-safe transition as soon as the power down sequence
is finalized.
If the VAON is set as an always-on regulator, the VAON output will remain enabled during a fault event
transitioning through the Fail-safe transition. If the VAON is set as a system regulator, the VAON output will be
disabled as defined in the power-down sequence.
All other system regulators are disabled as defined in the power-down sequence.
11.2.9.3 RESET state
A RESET state is provided to allow the system to refresh the configuration without looping through a full power
cycle.
During a reset event, the system can decide whether the VAON supply remains enabled, to maintain the
always-on domain or turn off to generate a full system reset condition.
When a reset event has occurred, the device turns off the system regulators as defined by the power-down
sequence, and it will power back up without the need of a new power-on event.
11.2.10 Fail-safe transition
During the Fail-safe transition, the VAON remains enabled if it is configured as an always-on regulator. All
system regulators will remain disabled until the next power-up sequence.
The state machine provides a Fail-safe counter (FS_CNT[3:0]) to prevent a non-recoverable cyclic failure from
happening.
PF09
All information provided in this document is subject to legal disclaimers.
© 2026 NXP B.V. All rights reserved.
Product data sheet
Rev. 1.3 — 16 December 2025
Document feedback
23 / 205



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com