| поискавой системы для электроныых деталей |
|
MPF0900AMMA2ES датащи(PDF) 27 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF0900AMMA2ES датащи(HTML) 27 Page - NXP Semiconductors |
|
27 / 205 page ![]() NXP Semiconductors PF09 Nine-channel power management IC with advanced system safety monitoring In Debug mode, the following conditions are valid: • I2C communication uses standard communication, with no CRC and secure write disabled • The default I2C address is 0x08, regardless of the address configured by OTP • Watchdog operation/monitoring is disabled • Secure write is disabled • XRESET pin is disabled • FCCU is disabled • DVSMIN and DVSMAX limits are disabled The PF09 can operate normally using the Debug mode configuration, as long as VIN does not go below the UVDET threshold. If VIN is lost (VIN < UVDET) the mirror registers will be reset, and Debug mode configuration must be performed again. The DBG_MODE flag is provided to indicate the device is in Debug mode. DBG_MODE Debug mode 0 Disabled 1 Enabled Table 21. Sys_Diag (register 0x82 ) 11.2.12.1.1 Test mode The device is able to operate in TEST mode. In TEST mode, the system shall be able to access the OTP mirror registers as well as all registers needed for OTP programming. In TEST mode, the following conditions are valid: • I2C communication uses standard communication, with no CRC and secure write disabled • The default I2C address is 0x08, regardless of the address configured by OTP • Watchdog operation/monitoring is disabled • Secure write is disabled • XRESET pin is disabled • FCCU is disabled • DVSMIN and DVSMAX limits are disabled 11.2.12.1.1.1 OTP emulation OTP Emulation mode allows the user to modify OTP mirror registers before powering up. This facilitates exercising different features of the PF09 while deciding on the best configuration for a given application. This is especially useful when optimizing the SWx compensation for the desired transient response. In emulation mode, only a VIN < UVDET or a critical DMS fault condition sends the device into the DFS state and causes a fuse reload upon exiting the DFS state. 11.2.12.1.1.2 OTP fuse programming OTP fuse burning is performed in the DBGOFF state. To burn the OTP fuses, devices must enter Test mode and write the desired values in the mirror registers. Once the proper configuration is set on the mirror registers, the device is configured. The programming command is executed while VDDOTP has a programming voltage between 7.5 V < VDDOTP < 8.5 V. PF09 All information provided in this document is subject to legal disclaimers. © 2026 NXP B.V. All rights reserved. Product data sheet Rev. 1.3 — 16 December 2025 Document feedback 27 / 205 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |