| поискавой системы для электроныых деталей |
|
ADPD6000 датащи(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADPD6000 датащи(HTML) 19 Page - Analog Devices |
|
19 / 89 page ![]() Data Sheet ADPD6000 THEORY OF OPERATION analog.com Rev. 0 | 19 of 89 ECG Main Signal Chain Figure 29 shows the ECG main signal chain diagram. Figure 29. ECG Main Signal Chain Diagram DCLO Detection The DCLO circuit injects a small programmable dc current into each input electrode and monitors the resulting electrode voltage. Figure 30 shows the DCLO detection diagram. Figure 30. DCLO Detection Diagram When both ECGIP and ECGIN, are properly connected, the current flow from one of the ECG inputs through the patient and into the other ECG input produces a minimal voltage shift. The fail current magnitude is common across all the ECG electrodes and programmable with a step size of 2 nA over a ±16 nA range using the ECG_DCLO_MAG bit field to change the magnitude. The polarity of the fail current is independent for each elec- trode and programmed using ECG_DCLO_POLARITY_IN and ECG_DCLO_POLARITY_IP. When an electrode connection de- grades or falls off, the pin voltage of that electrode is pulled high or low depending on the programmed fail current polarity. The DCLO detection circuit is based on each individual electrode input (ECGIP and ECGIN). The detection circuit is comparator based with independent programmable threshold levels for ECG inputs. For each input lead (ECGIP and ECGIN), there is only one compa- rator with a high-side threshold. For the RLD pin, there are two comparators with a high-side threshold and low-side threshold. These threshold limits are chosen such that all the threshold voltages cover the expected signal range. The window compara- tor compares the electrode input voltage with the corresponding threshold voltages. Where the voltage change on a particular electrode exceeds one of the programmed threshold voltages for that fail current, the dc resistance of the electrode contact can be determined to flag a lead off. ACLO Detection The ECG path has an ACLO detection circuit that can be used for lead off detection with the DCLO detection circuit to deal with differ- ent types of lead. Figure 31 shows the ACLO detection diagram. Figure 31. ACLO Detection Diagram The ACLO method of sensing if the electrodes are connected to the patient is based on injecting ac currents into each ECG electrode and measuring the amplitudes of the resulting voltages through the ECG channel. The ECG channel must be enabled to use the ACLO function. The magnitude of the ACLO current is programmable through the ECG_ACLO_MAG bit field. The ac current is driven out onto the ECG input paths and establishes a voltage between the ECG channel inputs where it is measured. The measured voltage is synchronously demodulated and sent through a comparator. The user can set the threshold though the ECG_ACLO_THRESHOLD bit field. ACLO detection functions only on the ECG input pins (ECGIP and ECGIN) and is not supported for the RLD pin. A properly connected electrode has a small signal because the drive current flows into the right leg (RL). An improperly connected or dried out electrode has a larger signal as determined by a capacitive voltage divider. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |