87 / 89 page ![]() Data Sheet ADPD6000 REGISTER DETAILS analog.com Rev. 0 | 87 of 89 Table 21. Register Details Reg Name Bits Bit Name Description Reset Access 0010: connect TIA input to IMPIN. 0100: connect TIA input to EXCP. 1000: connect TIA input to EXCN. [5:2] BIOZ_DSW_x Switch mux for excitation buffer output. 0x0 R/W 0001: connect excitation buffer output to IMPIP. 0010: connect excitation buffer output to IMPIN. 0100: connect excitation buffer output to EXCP. 1000: connect excitation buffer output to EXCN. 1 BIOZ_TRSW_x T switch in mux for RCALx. 0x0 R/W 0: disconnect RCALx to HPTIA. 1: connect RCALx to HPTIA. 0 BIOZ_DRSW_x D switch in mux for RCALx. 0x0 R/W 0: disconnect RCALx to excitation buffer. 1: connect RCALx to excitation buffer. 0x02AC BIOZ_ANA_CTRL3_A [15:2] RESERVED Reserved. 0x0 R 0x02CC BIOZ_ANA_CTRL3_B [1:0] BIOZ_RINT_SW_x Support internal calibration resistor. Set to 0x11 to enable the internal calibration resolution. 0x0 R/W 0x02EC BIOZ_ANA_CTRL3_C 00: floating internal calibration resistance. 0x030C BIOZ_ANA_CTRL3_D 11: connect internal calibration resistance to excitation buffer and HPTIA. 0x032C BIOZ_ANA_CTRL3_E 0x034C BIOZ_ANA_CTRL3_F 0x02AD BIOZ_ADCFILTERCON_A [15:6] RESERVED Reserved. 0x0 R 0x02CD BIOZ_ADCFILTERCON_B [5:4] BIOZ_AVRGNUM_x Sets number of samples used by the averaging function. 0x0 R/W 0x02ED BIOZ_ADCFILTERCON_C 00: Two ADC samples. 0x030D BIOZ_ADCFILTERCON_D 01: Four ADC samples. The number of input data for one average is four. 0x032D BIOZ_ADCFILTERCON_E 10: Eight ADC samples. The number of input data for one average is eight. 0x034D BIOZ_ADCFILTERCON_F 11: 16 ADC samples. The number of input data for one average is 16. 3 BIOZ_AVRGEN_x Average function enable. Enable average operation of SINC3 filter output 0x0 R/W 0: disable. SINC3 filter result fed to the next stage directly. 1: enable. Averaged result fed to the next stage. 2 BIOZ_SINC3BYP_x Bypass SINC3 filter. 0x0 R/W 0: enable SINC3 filter. 1: bypass SINC3 filter. [1:0] BIOZ_SINC3OSR_x SINC3 filter oversampling rate. 0x0 R/W 00: oversampling rate of five. 01: oversampling rate of four. 10: oversampling rate of two. 11: oversampling rate of five. 0x02AE BIOZ_DFTCON_A [15:6] RESERVED Reserved. 0x0 R 0x02CE BIOZ_DFTCON_B 5 BIOZ_WG_DFT_DIFF_PHASE_E N_x Wave generator block sine wave and DFT block sine wave use a different offset. 0x0 R/W 0x02EE BIOZ_DFTCON_C 0: use the same offset. 0x030E BIOZ_DFTCON_D 1: use the different offset. 0x032E BIOZ_DFTCON_E 4 BIOZ_HANNINGEN_x Enable Hanning window. 0x0 R/W |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |