| поискавой системы для электроныых деталей |
|
LP8733 датащи(PDF) 31 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LP8733 датащи(HTML) 31 Page - Texas Instruments |
|
31 / 85 page ![]() V(VANA) VANA_UVLO State Shut down Read OTP Standby PGOOD pin EN pin VOUT (Buck1) VOUT (LDO0) Buck1 internal powergood LDO0 internal powergood Active 800us Timer Buck internal enable 800us Timer LDO0 internal enable 4ms 2ms Clear fault 31 LP8733-Q1 www.ti.com SNVSB64 – SEPTEMBER 2018 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated Figure 17. PGOOD Pin Operation in Gated Mode 7.3.8.1.2 PGOOD Pin Continuous Mode The continuous (or unvalid) mode of operation is selected by setting PGOOD_MODE bit to 1 in PGOOD_CTRL_2 register. For the continuous mode of operation, PGOOD behaves as follows: • PGOOD is set to active or asserted state upon exiting OTP configuration. • PGOOD is set to inactive or de-asserted as soon as regulator is enabled. • PGOOD status begins indicating output voltage regulation status immediately and continuously. • During power-up sequencing and requested voltage changes, PGOOD will toggle between inactive or de- asserted while output voltages are outside of regulation ranges and active or asserted when inside of regulation ranges. The PG_FAULT register bits are latched and maintain the fault information until host clears the fault bit by writing 1 to the bit. The PGOOD signal indicates also a thermal shutdown and input overvoltage interrupts, which are cleared by clearing the interrupt bits. When regulator voltage is transitioning from one target voltage to another, the PGOOD signal is set inactive. When the PGOOD signal becomes inactive, the source for the fault can be read from PG_FAULT register. If the invalid output voltage becomes valid again the PGOOD signal becomes active. Thus the PGOOD signal shows all the time if the monitored output voltages are valid. The block diagram for this operation is shown in Figure 18 and an example of operation is shown in Figure 19. The PGOOD signal can be also configured so that it maintains inactive state even when the monitored outputs are valid but there are PG_FAULT_x bits in PG_FAULT register pending clearance. This type of operation is selected by setting PGFAULT_GATES_PGOOD bit to 1 in PGOOD_CTRL_2 register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |