| поискавой системы для электроныых деталей |
|
CS5530A датащи(PDF) 72 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
CS5530A датащи(HTML) 72 Page - National Semiconductor (TI) |
|
72 / 259 page ![]() www.national.com 72 Revision 1.1 Functional Description (Continued) Although not considered as device idle timers, two addi- tional timers are provided by the CS5530A. The Video Idle Timer used for Suspend determination and the VGA Timer used for SoftVGA. These timers and their associated programming bits are listed in Tables 3-26 and 3-27. Table 3-26. Video Idle Timer and Trap Related Registers Bit Description F0 Index 81h Power Management Enable Register 2 (R/W) Reset Value = 00h 7 Video Access Idle Timer Enable: Load timer from Video Idle Timer Count Register (F0 Index A6h) and generate an SMI when the timer expires. 0 = Disable; 1 = Enable. If an access occurs in the video address range (sets bit 0 of the GX-series processor’s PSERIAL register) the timer is reloaded with the programmed count. Top level SMI status is reported at F1BAR+Memory Offset 00h/02h[0]. Second level SMI status is reported at F0 Index 85h/F5h[7]. F0 Index 82h Power Management Enable Register 3 (R/W) Reset Value = 00h 7 Video Access Trap: 0 = Disable; 1 = Enable. If this bit is enabled and an access occurs in the video address range (sets bit 0 of the GX-series processor’s PSERIAL register) an SMI is generated. Top level SMI status is reported at F1BAR+Memory Offset 00h/02h[0]. Second level SMI status is reported at F0 Index 86h/F6h[7]. F0 Index A6h-A7h Video Idle Timer Count Register (R/W) Reset Value = 0000h 15:0 Video Idle Timer Count: The idle timer loaded from this register determines when the graphics subsystem has been idle as part of the Suspend determination algorithm. The 16-bit value programmed here represents the period of video inactivity after which the system is alerted via an SMI. The count in this timer is automatically reset whenever an access occurs to the graphics controller space. The timer uses a 1 second timebase. In a GX-series processor based system the graphics controller is embedded in the CPU, so video activity is communicated to the CS5530A via the serial connection (PSERIAL register, bit 0) from the processor. The CS5530A also detects accesses to standard VGA space on PCI (3Bxh, 3Cxh, 3Dxh and A000h-B7FFh) in the event an external VGA controller is being used. To enable this timer set F0 Index 81h[7] = 1. Top level SMI status is reported at F1BAR+Memory Offset 00h/02h[0]. Second level SMI status is reported at F0 Index 85h/F5h[7]. Table 3-27. VGA Timer Related Registers Bit Description F0 Index 83h Power Management Enable Register 4 (R/W) Reset Value = 00h 3 VGA Timer Enable: Turn on VGA Timer and generate an SMI when the timer reaches 0. 0 = Disable; 1 = Enable. VGA Timer programming is at F0 Index 8Eh and F0 Index 8Bh[6]. To reload the count in the VGA timer, disable it, optionally change the count value in F0 Index 8Eh[7:0], and reenable it before enabling power management. SMI Status reporting is at F1BAR+Memory Offset 00h/02h[6] (only). Although grouped with the power management Idle Timers, the VGA Timer is not a power management function. The VGA Timer counts whether power management is enabled or disabled. F0 Index 8Bh General Purpose Timer 2 Control Register (R/W) Reset Value = 00h 6 VGA Timer Base: Selects timebase for VGA Timer Register (F0 Index 8Eh). 0 = 1 ms; 1 = 32 µs. F0 Index 8Eh VGA Timer Count Register 7:0 VGA Timer Load Value: This register holds the load value for the VGA timer. The value is loaded into the timer when the timer is enabled (F0 Index 83h[3] = 1). The timer is decremented with each clock of the configured timebase (F0 Index 8Bh[6]). Upon expiration of the timer, an SMI is generated and the status is reported in F1BAR+Memory Offset 00h/02h[6] (only). Once expired, this timer must be re-initialized by disabling it (F0 Index 83h[3] = 0) and then enabling it (F0 Index 83h[3] = 1). When the count value is changed in this register, the timer must be re-initialized in order for the new value to be loaded. This timer’s timebase is selectable as 1 ms (default) or 32 µs. (F0 Index 8Bh). Note: Although grouped with the power management Idle Timers, the VGA Timer is not a power management function. It is not affected by the Global Power Management Enable setting at F0 Index 80h[0]. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |