| поискавой системы для электроныых деталей |
|
TUSB3410 датащи(PDF) 43 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TUSB3410 датащи(HTML) 43 Page - Texas Instruments |
|
43 / 92 page ![]() 6–3 6.1.2 DMACSR1: DMA Control And Status Register (UART Transmit Channel) (Addr:FFE1) This register is used to define the transaction time-out value. In addition, it contains a completion code that reports any errors or a time-out condition. 765 4 3 2 1 0 TEN C4 C3 C2 C1 C0 TXFT PPKT R/W R/W R/W R/W R/W R/W R/C R/C BIT NAME RESET FUNCTION 0 PPKT 0 Partial packet condition bit. This bit is set by the DMA and cleared by the MCU (see Table 6–2). PPKT = 0 No partial-packet condition PPKT = 1 Partial-packet condition detected. When IEN = 0, this bit does not clear the EN bit in DMACDR; therefore, the DMAC stays enabled, ready for the next transaction. Clears when MCU writes a 1. Writing a 0 has no effect. 1 TXFT 0 Transfer time-out condition (see Table 6–2) TXFT = 0 DMA stopped transfer without time-out TXFT = 1 DMA stopped due to transaction time-out. When IEN = 0, this bit does not clear the EN bit in DMACDR; therefore, the DMAC stays enabled, ready for the next transaction. DMA clears when the MCU writes a 1. Writing a 0 has no effect. 6–2 C[4:0] 0 This field is used to define the transaction time-out value in 1-ms increments. This value is loaded to a down counter every time a byte transfer occurs. The down counter is decremented every SOF pulse (1 ms). If the counter decrements to zero it sets TXFT = 1 (in DMACSR register) and halts the DMA transfer. The counter starts counting only when TEN = 1 and EN = 1 (in DMACDR) and the first byte has been transmitted (see Figure 6–1). 00000 = 0-ms time-out : : 11111 = 31-ms time-out 7 TEN 0 Transaction time-out counter enable/disable bit. TEN = 0 TEN = 1 Counter is disabled (does not time-out) Counter is enabled Table 6–2. DMA OUT-Termination Condition OUT TERMINATION TXFT PPKT COMMENTS UART partial packet 0 1 This condition occurs when the host sends a partial packet. UART time-out 1 0 This condition occurs when X- and Y-output buffers are full and the UART transmitter cannot transmit (due to flow-control restriction) or if host has no data to transmit. Counter C[4:0] TXFT Load SOF TEN EN Figure 6–1. Transaction Time-Out Diagram |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |