26 / 44 page ![]() REV. 0 –26– ADE7754 APPARENT ENERGY CALCULATION The apparent energy is given as the integral of the apparent power. Apparent Energy Apparent Power t dt = ∫ () (21) The ADE7754 achieves the integration of the apparent power signal by continuously accumulating the apparent power signal in an internal nonreadable 49-bit register. The apparent energy register (VAENERGY[23:0]) represents the upper 24 bits of this internal register. This discrete time accumulation or summa- tion is equivalent to integration in continuous time. Equation 22 expresses the relationship, where n is the discrete time sample number and T is the sample period. Apparent Energy Lim Apparent Power nT T T n =× → = ∞ ∑ 0 0 () (22) The discrete time sample period (T) for the accumulation regis- ter in the ADE7754 is 1.2 µs (12/10 MHz). Figure 37 shows a graphical representation of this discrete time integration or accumulation. The apparent power signal is continuously added to the internal register. This addition is a signed addition even if the apparent energy theoretically always remains positive. 48 0 + 48 0 VAENERGY[23:0] VADIV 23 0 % TOTAL APPARENT POWER IS ACCUMULATED (INTEGRATED) IN THE APPARENT ENERGY REGISTER TOTAL APPARENT POWER T + 00000h D1B71h TIME (nT) T APPARENT POWER SIGNAL – P Figure 37. Apparent Energy Calculation The upper 49-bit value of the internal register is divided by VADIV. If the value in the VADIV register is 0, then the internal active energy register is divided by 1. VADIV is an 8-bit unsigned register. The upper 24-bit values are then written in the 24-bit apparent energy register (VAENERGY[23:0]). RVAENERGY register (24 bits long) is provided to read the apparent energy. This register is reset to 0 after a read operation. Figure 38 shows this apparent energy accumulation for full-scale (sinusoidal) signals on the analog inputs. The three curves illus- trate the minimum time it takes the energy register to roll over when the individual VA gain registers contents all equal 3FFh, 000h, and 800h. The VA gain registers are used to carry out an apparent power calibration in the ADE7754. The fastest integra- tion time occurs when the VA gain registers are set to maximum full scale (i.e., 3FFh). 00,0000h 7F,FFFFh 80,0000h 3F,FFFFh 40,0000h VAENERGY[23:0] TIME (sec) AVAG = BVAG = CVAG = 3FFh 131 262 393 65.5 AVAG = BVAG = CVAG = 000h AVAG = BVAG = CVAG = 800h 196.5 327.5 Figure 38. Energy Register Roll Over Time for Full- Scale Power (Minimum and Maximum Power Gain) Note that the apparent energy register contents roll over to full- scale negative (80,0000h) and continue increasing in value when the power or energy flow is positive, as shown in Figure 38. By using the interrupt enable register, the ADE7754 can be config- ured to issue an interrupt (IRQ) when the apparent energy register is half full (positive or negative). Integration Times under Steady Load As described in the preceding section, the discrete time sample period (T) for the accumulation register is 1.2 µs (12/CLKIN). With full-scale sinusoidal signals on the analog inputs and the VA gain registers set to 000h, the average word value from each apparent power stage is D1B71h. See the Apparent Power Calculation section. The maximum value that can be stored in the apparent energy register before it overflows is 22 3 – 1 or FF,FFFFh. As the average word value is added to the internal register that can store 248 – 1 or FFFF,FFFF,FFFFh before it overflows, the integration time under these conditions with VADIV = 0 is calculated as follows: Time FFFF FFFF FFFFh DB h ss s = × ×= = ,, . min 31 71 12 131 2 11 µ When VADIV is set to a value different from 0, the integration time varies as shown in Equation 23. Time Time VADIV WDIV =× =0 (23) LINE APPARENT ENERGY ACCUMULATION The ADE7754 is designed with a special apparent energy accu- mulation mode that simplifies the calibration process. By using the on-chip zero-crossing detection, the ADE7754 accumulates the apparent power signal in the LVAENERGY register for an integral number of half cycles, as shown in Figure 39. The line apparent energy accumulation mode is always active. Each of three zero-crossing detection phases can contribute to the accumulation of the half line cycles. Phase A, B, and C zero crossings are taken into account when counting the number of half line cycles by setting Bits 4 to 6 of the MMODE register to Logic 1. Selecting phases for the zero-crossing counting also has the effect of enabling the zero-crossing detection, zero-crossing timeout, and period measurement for the corresponding phase as described in the zero-crossing detection paragraph. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |