| поискавой системы для электроныых деталей |
|
ADE7754 датащи(PDF) 15 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7754 датащи(HTML) 15 Page - Analog Devices |
|
15 / 44 page ![]() REV. 0 ADE7754 –15– are particularly noticeable at low power factors. The ADE7754 provides a means of digitally calibrating these small phase errors. The ADE7754 allows a small time delay or time advance to be introduced into the signal processing chain to compensate for small phase errors. Because the compensation is in time, this technique should be used only for small phase errors in the range of 0.1 ° to 0.5°. Correcting large phase errors using a time shift technique can introduce significant phase errors at higher harmonics. The phase calibration registers (APHCAL, BPHCAL, and CPHCAL) are twos complement, 5-bit signed registers that can vary the time delay in the voltage channel signal path from –19.2 µs to +19.2 µs (CLKIN = 10 MHz). One LSB is equiva- lent to 1.2 µs. With a line frequency of 50 Hz, this gives a phase resolution of 0.022 ° at the fundamental (i.e., 360° 1.2 µs 50 Hz). Figure 19 illustrates how the phase compensation is used to remove a 0.091 ° phase lead in IA of the current channel caused by an external transducer. In order to cancel the lead (0.091 °) in IA of the current channel, a phase lead must also be intro- duced into VA of the voltage channel. The resolution of the phase adjustment allows the introduction of a phase lead of 0.086 °. The phase lead is achieved by introducing a time advance into VA. A time advance of 4.8 µs is made by writing –4 (1Ch) to the time delay block (APHCAL[4:0]), thus reducing the amount of time delay by 4.8 µs. See the Calibration of a 3-Phase Meter Based on the ADE7754 Application Note AN-624. V1 V2 0.1 50Hz IA VA IAP IAN ADC IA PGA1 HPF VAP VN ADC VA PGA2 0.69 AT 50Hz, 0.022 0.83 AT 60Hz, 0.024 LPF2 24 1 VA DELAYED BY 4.8 s (–0.0868 AT 50Hz) 1CH 50Hz APHCAL[4:0] –19.2 s TO +19.2 s 0 0 1 0 1 1 0 0 0 7 24 Figure 19. Phase Calibration ROOT MEAN SQUARE MEASUREMENT Root Mean Square (rms) is a fundamental measurement of the magnitude of an ac signal. Its definition can be practical or mathematical. Defined practically, the rms value assigned to an ac signal is the amount of dc required to produce an equivalent amount of heat in the same load. Mathematically the rms value of a continuous signal f(t) is defined as F T ft dt rms T = × ∫ 1 0 2() (1) For time sampling signals, rms calculation involves squaring the signal, taking the average, and obtaining the square root: F N fi rms i N = = × ∑ 1 2 1 () (2) The method used to calculate the rms value in the ADE7754 is to low-pass filter the square of the input signal (LPF3) and take the square root of the result. With Vt V t rms () sin( ) =× × 2 ω then Vt Vt V V t rms rms () () cos( ) ×= − × 22 2 ω The rms calculation is simultaneously processed on the six analog input channels. Each result is available on separate registers. Current RMS Calculation Figure 20 shows the detail of the signal processing chain for the rms calculation on one of the phases of the current channel. The current channel rms value is processed from the samples used in the current channel waveform sampling mode. Note that the APGAIN adjustment affects the result of the rms calcu- lation. See the Current RMS Gain Adjust section. The current rms values are stored in unsigned 24-bit registers (AIRMS, BIRMS, and CIRMS). One LSB of the current rms register is equivalent to 1 LSB of a current waveform sample. The update rate of the current rms measurement is CLKIN/12. With the specified full-scale analog input signal of 0.5 V, the ADC produces an output code which is approximately ±2,684,354d. See the Current Channel ADC section. The equivalent rms values of a full-scale ac signal is 1,898,124d. With offset calibration, the current rms measurement provided in the ADE7754 is accurate within ±2% for signal input between full scale and full scale/100. CURRENT SIGNAL – i(t) CURRENT CHANNEL (rms) 0000h 1CF68Ch + 100% FS FS – 100% FS E30974h + 122.5% FS + 70.7% FS – 70.7% FS – 122.5% FS 2378EDh 147AE0h EB852Fh DC8713h AAPGAIN[11:0] 000h 7FFh 800h 00000h 400000h C00000h 28F5C2h D70A3Eh + FS – FS ADC OUTPUT WORD RANGE IA AAPGAIN HPF LPF3 211 SGN 29 210 22 20 21 Irms(t) –100% to +100% FS 1CF68Ch 00h IRMS IRMSOS[11:0] 24 24 + Figure 20. Current RMS Signal Processing Note that a crosstalk between phases can appear in the ADE7754 current rms measurements. This crosstalk follows a specific |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |