ADE7754 датащи(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7754 датащи(HTML) 19 Page - Analog Devices |
|
19 / 44 page ![]() REV. 0 ADE7754 –19– HPF – IB* + AAPGAIN LPF2 AWGAIN AAPOS + 1 28 IA VA PHASE A 0 HPF IB* BAPGAIN LPF2 BWGAIN BAPOS + 1 28 IB VB PHASE B HPF – IB* + CAPGAIN LPF2 CWGAIN CAPOS + 1 28 IC VC PHASE C 0 TOTAL INSTANTANEOUS POWER SIGNAL ACTIVE POWER SIGNAL – P 2752545h Figure 26. Total Active Power Consumption Calculation For example, for WATMOD = 1, when all the gains and offsets corrections are taken into consideration, the formula that is used to process the active power is Total Active Power V AAPGAIN I BAPGAIN I AAPOS AWG V CAPGAIN I BAPGAIN I CAPOS CWG AA B CC B = ×+ ×− + × + ×+ +× + ×− + × + ×+ 1 2 1 2 1 2 1 2 1 2 1 2 12 12 12 12 12 12 12 Depending on the polyphase meter service, an appropriate for- mula should be chosen to calculate the active power. The American ANSI C12.10 standard defines the different configu- rations of the meter. Table II describes which mode should be chosen for each configuration. Table II. Meter Form Configuration ANSI Meter Form WATMOD WATSEL 5S/13S 3-wire Delta 0 3 or 5 or 6 6S/14S 4-wire Wye 1 5 8S/15S 4-wire Delta 2 5 9S/16S 4-wire Wye 0 7 Different gain calibration parameters are offered in the ADE7754 to cover the calibration of the meter in different configurations. Note that in Mode 0, the APGAIN and WGAIN registers have the same effect on the end result. In this case, APGAIN regis- ters should be set at their default value and the gain adjustment should be made with the WGAIN registers. ENERGY CALCULATION As stated earlier, power is defined as the rate of energy flow. This relationship can be expressed mathematically as P dE dt = (7) where P = power and E = energy. Conversely energy is given as the integral of power. E Pdt = ∫ (8) The ADE7754 achieves the integration of the active power signal by continuously accumulating the active power signal in an internal non readable 54-bit energy register. The active energy register (AENERGY[23:0]) represents the upper 24 bits of this internal register. This discrete time accumulation or summation is equivalent to integration in continuous time. Equation 9 expresses the relationship Ep t dt Lim p nT T Tn == ∫ × →= ∞ () ( ) 00 Σ (9) where n is the discrete time sample number and T is the sample period. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |