22 / 44 page ![]() REV. 0 –22– ADE7754 by setting to Logic 1 Bit 3 of the gain register (Address 18h). See Table X. Any load generating an active power amplitude lower than the minimum amplitude specified will not be taken into account when accumulating the active power from this phase. The minimum instantaneous active power allowed in this mode is 0.005% of the full-scale amplitude. Because the maximum active power value is 13,743,895d with full-scale analog input, the no-load threshold is 687d. For example, an energy meter with maximum inputs of 220 V and 40 A and Ib = 10 A, the maximum instantaneous active power is 3,435,974d, assuming that both inputs represent half of the analog input full scale. As the no-load threshold represents 687d, the start-up current represents 8 mA or 0.08% of Ib. Mode Selection of the Sum of the Three Active Energies The ADE7754 can be configured to execute the arithmetic sum of the three active energies, Wh = Wh A + Wh B + Wh C, or the sum of the absolute value of these energies, Wh = |Wh A| + |Wh B| + |Wh C|. The selection between the two modes can be made by setting Bit 2 of the gain register (Address 18h). See Table X. Logic high and logic low of this bit correspond to the sum of absolute values and the arithmetic sum, respectively. This selection affects the active energy accumulation in the AENERGY, RAENERGY, and LAENERGY registers as well as the CF frequency output. When the sum of the absolute values is selected, the active energy from each phase is always counted positive in the total active energy. It is particularly useful in a 3-phase, 4-wire instal- lation where the sign of the active power should always be the same. If the meter is misconnected to the power lines (e.g., CT is connected in the wrong direction), the total active energy recorded without this solution can be reduced by two thirds. The sum of the absolute values ensures that the active energy recorded represents the actual active energy delivered. In this mode, the reverse power information available in the CFNUM register is still detecting when negative active power is present on any of the three phase inputs. LINE ENERGY ACCUMULATION The ADE7754 is designed with a special energy accumulation mode that simplifies the calibration process. By using the on- chip zero-crossing detection, the ADE7754 accumulates the active power signal in the LAENERGY register for an integer number of half cycles, as shown in Figure 31. The line active energy accumulation mode is always active. Using this mode with only one phase selected is recommended. If several phases are selected, the amount accumulated may be smaller than it should be. Each one of three phases zero-crossing detection can contribute to the accumulation of the half line cycles. Phase A, B, and C zero crossings, respectively, are taken into account when count- ing the number of half line cycles by setting Bits 4 to 6 of the MMODE register to Logic 1. Selecting phases for the zero- crossing counting also has the effect of enabling the zero-cross- ing detection, zero-crossing timeout and period measurement for the corresponding phase as described in the zero-crossing detection paragraph. The number of half line cycles is specified in the LINCYC register. LINCYC is an unsigned 16-bit register. The ADE7754 can accumulate active power for up to 65535 combined half cycles. Because the active power is integrated on an integer number of line cycles, the sinusoidal component is reduced to zero. This eliminates any ripple in the energy calculation. Energy is calculated more accurately because of this precise timing control. At the end of an energy calibration cycle, the LINCYC flag in the interrupt status register is set. If the LINCYC enable bit in the interrupt enable register is set to Logic 1, the IRQ output also goes active low. 51 0 + 51 0 AENERGY[23:0] WDIV 23 0 % POWER PHASE B POWER PHASE A POWER PHASE C + + + LPF1 FROM VA ADC ZERO-CROSS DETECT MMODE REGISTER BIT 4 LPF1 FROM VB ADC ZERO-CROSS DETECT MMODE REGISTER BIT 5 LPF1 FROM VC ADC ZERO-CROSS DETECT MMODE REGISTER BIT 6 CALIBRATION CONTROL LINCYC[15:0] ACCUMULATE ACTIVE POWER DURING LINCYC ZERO CROSSINGS Figure 31. Active Energy Calibration |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |