| поискавой системы для электроныых деталей |
|
OR4E2 датащи(PDF) 62 Page - Agere Systems |
|
|
|||||||||||||||||||||||||||||
OR4E2 датащи(HTML) 62 Page - Agere Systems |
|
62 / 124 page ![]() 62 Lucent Technologies Inc. Preliminary Data Sheet December 2000 ORCA Series 4 FPGAs FPGA States of Operation (continued) Table 37. Configuration Frame Size Devices OR4E2 OR4E4 OR4E6 OR4E10 OR4E14 Number of Frames 1796 2436 3076 3972 4356 Data Bits/Frame 900 1284 1540 1924 2372 Maximum Configuration Data (Number of bits/frame x Number of frames) 1,610,400 3,127,824 4,737,040 7,642,128 10,332,432 Maximum PROM Size (bits) (add configuration header and postamble) 1,161,648 3,128,072 4,737,288 7,642,376 10,332,680 Bit Stream Error Checking There are three different types of bit stream error checking performed in the ORCA Series 4 FPGAs: ID frame, frame alignment, and CRC checking. The ID data frame is sent to a dedicated location in the FPGA. This ID frame contains a unique code for the device for which it was generated. This device code is compared to the internal code of the FPGA. Any differ- ences are flagged as an ID error. This frame is auto- matically created by the bit stream generation program in ORCA Foundry. Each data and address frame in the FPGA begins with a frame start pair of bits and ends with eight stop bits set to 1. If any of the previous stop bits were a 0 when a frame start pair is encountered, it is flagged as a frame alignment error. Error checking is also done on the FPGA for each frame by means of a checksum byte. If an error is found on evaluation of the checksum byte, then a checksum/ parity error is flagged. The checksum is the XOR of all the data bytes, from the start of frame up to and includ- ing the bytes before the checksum. It applies to the ID, address, and data frames. When any of the three possible errors occur, the FPGA is forced into an idle state, forcing INIT low. The FPGA will remain in this state until either the RESET or PRGM pins are asserted. Also the pin CFQ_IRQ/MPI_IRQ is forced low to signal the error and the specific type of bit stream error is written to one of the system bus regis- ters by the FPGA configuration logic. The PGRM bit of the system bus control register can also be used to reset out of the error condition and restart configura- tion. FPGA Configuration Modes There are twelve methods for configuring the FPGA. Eleven of the configuration modes are selected on the M0, M1, and M2 inputs. The twelfth configuration mode is accessed through the boundary-scan interface. A fourth input, M3, is used to select the frequency of the internal oscillator, which is the source for CCLK in some configuration modes. The nominal frequencies of the internal oscillator are 1.25 MHz and 10 MHz. The 1.25 MHz frequency is selected when the M3 input is unconnected or driven to a high state. There are three basic FPGA configuration modes: master, slave, and peripheral. The configuration data can be transmitted to the FPGA serially or in parallel bytes. As a master, the FPGA provides the control sig- nals out to strobe data in. As a slave device, a clock is generated externally and provided into the CCLK input. In the three peripheral modes, the FPGA acts as a microprocessor peripheral. Table 38 lists the functions of the configuration mode pins. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |