| поискавой системы для электроныых деталей |
|
MFRC63002R датащи(PDF) 51 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MFRC63002R датащи(HTML) 51 Page - NXP Semiconductors |
|
51 / 118 page ![]() MFRC630 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved. Product data sheet COMPANY PUBLIC Rev. 3.1 — 6 September 2012 227531 51 of 118 NXP Semiconductors MFRC630 Contactless reader IC The content of the FIFO is transmitted immediately after starting the command. Before transmitting the FIFO content all relevant register have to be set to transmit data. This command terminates automatically when the FIFO gets empty. It can be terminated by any other command written to the command register. 8.10.3.7 Transceive command Command (07h); This command transmits data from the FIFO and receives data from the RF field at once. The first action is transmitting and after a transmission the command is changed to receive a data stream. Each transmission process starts by writing the command into CommandReg. Remark: If the bit RxMultiple in register RxModeReg is set to logic 1, this command will never leave the receiving state, because the receiving will not be cancelled automatically. 8.10.3.8 WriteE2 command Command (08h), Parameter1 (addressL), Parameter2 (addressH), Parameter3 (data); This command writes one byte into the EEPROM. If the FIFO contains no data, the command will wait until the data is available. Abort condition: insufficient parameter in FIFO; Address-parameter outside of range. 8.10.3.9 WriteE2PAGE command Command (09h), Parameter1 (page address), Parameter2 (data0), Parameter3...65 [data1 ..data63]; This command writes up to 64 bytes into the EEPROM. Abort condition: Insufficient parameters in FIFO; Page address parameter outside of range. 8.10.3.10 ReadE2 command Command (0Ah), Parameter1 (addressL), Parameter2 (addressH), Parameter3 (length); Reads up to 256 bytes from the EEPROM to the FIFO. If a read operation exceeds the address 1FFFh, the read operation continues from address 0000h. Abort condition: Insufficient parameter in FIFO; Address parameter outside of range. 8.10.3.11 LoadReg command Command (0Ch), Parameter1 (EEPROM addressL),Parameter2 (EEPROM addressH), Parameter3 (RegAdr), Parameter4 (number); Read a defined number of bytes from the EEPROM and copies the value into the Register set, beginning at the given address RegAdr. Abort condition: Insufficient parameter in FIFO; Address parameter outside of range. 8.10.3.12 LoadProtocol command Command (0Dh), Parameter1 (Protocol number RX), Parameter2 (Protocol number TX); |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |