71 / 76 page ![]() AD9522-5 Rev. 0 | Page 71 of 76 Reg. Addr (Hex) Bit(s) Name Description 19B [2] Channel 3 power-down Channel 3 powers down. [2] = 0; normal operation (default). [2] = 1; powered down. (OUT9/OUT9, OUT10/OUT10, and OUT11/OUT11 are put into the high impedance power-down mode by setting this bit.) 19B [0] Disable Divider 3 DCC Duty-cycle correction function. [0] = 0; enable duty-cycle correction (default). [0] = 1; disable duty-cycle correction. Table 50. VCO Divider and CLK Input Reg. Addr (Hex) Bit(s) Name Description 1E0 [2:0] VCO divider [2] [1] [0] Divide 0 0 0 2 (default) 0 0 1 3 0 1 0 4 0 1 1 5 1 0 0 6 1 0 1 Output static 1 1 0 1 (bypass) 1 1 1 Output static 1E1 [4] Power-down clock input section Powers down the clock input section (including CLK buffer, VCO divider, and CLK tree). [4] = 0; normal operation (default). [4] = 1; power down. 1E1 [0] Bypass VCO divider Bypasses or uses the VCO divider. [0] = 0; use VCO divider (default). [0] = 1; bypass VCO divider. Table 51. System Reg. Addr (Hex) Bit(s) Name Description 230 [3] Disable power-on SYNC Power-on SYNC mode. Used to disable the antiruntpulse circuitry. [3] = 0; enable the antiruntpulse circuitry (default). [3] = 1; disable the antiruntpulse circuitry. 230 [2] Power-down SYNC Powers down the SYNC function. [2] = 0; normal operation of the SYNC function (default). [2] = 1; power-down the SYNC circuitry. 230 [1] Power-down distribution reference Powers down the reference for the distribution section. [1] = 0; normal operation of the reference for the distribution section (default). [1] = 1; powers down the reference for the distribution section. 230 [0] Soft SYNC The soft SYNC bit works the same as the SYNC pin, except that the polarity of the bit is reversed; that is, a high level forces the selected channels into a predetermined static state, and a 1-to-0 transition triggers a SYNC. [0] = 0; same as SYNC high. [0] = 1; same as SYNC low. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |