86 / 156 page ![]() XRT86VL34 81 QUAD T1/E1/J1 FRAMER/LIU COMBO - T1 REGISTER DESCRIPTION REV. V1.2.0 . . TABLE 62: PMON RECEIVE FRAMING ALIGNMENT BIT ERROR COUNTER MSB (RFAECU) HEX ADDRESS: 0Xn902 BIT FUNCTION TYPE DEFAULT DESCRIPTION-OPERATION 7 RFAEC[15] RUR 0 Performance Monitor “Receive Framing Alignment Error 16-Bit counter” - Upper Byte: These RESET-upon-READ bits, along with that within the “PMON Receive Framing Alignment Error Counter Register LSB” combine to reflect the cumulative number of instances that the Receive Framing Alignment errors has been detected by the Receive T1 Framer block since the last read of this register. This register contains the Most Significant byte of this 16-bit of the Receive Framing Alignment Error counter. NOTE: For all 16-bit wide PMON registers, user must read the MSB counter first before reading the LSB counter in order to read the accurate PMON counts. To clear PMON count, user must read the MSB counter first before reading the LSB counter in order to clear the PMON count. 6 RFAEC[14] RUR 0 5 RFAEC[13] RUR 0 4 RFAEC[12] RUR 0 3 RFAEC[11] RUR 0 2 RFAEC[10] RUR 0 1 RFAEC[9] RUR 0 0 RFAEC[8] RUR 0 TABLE 63: PMON RECEIVE FRAMING ALIGNMENT BIT ERROR COUNTER LSB (RFAECL) HEX ADDRESS: 0Xn903 BIT FUNCTION TYPE DEFAULT DESCRIPTION-OPERATION 7 RFAEC[7] RUR 0 Performance Monitor “Receive Framing Alignment Error 16-Bit Counter” - Lower Byte: These RESET-upon-READ bits, along with that within the “PMON Receive Framing Alignment Error Counter Register MSB” combine to reflect the cumulative number of instances that the Receive Framing Alignment errors has been detected by the Receive T1 Framer block since the last read of this register. This register contains the Least Significant byte of this 16-bit of the Receive Framing Alignment Error counter. NOTE: For all 16-bit wide PMON registers, user must read the MSB counter first before reading the LSB counter in order to read the accurate PMON counts. To clear PMON count, user must read the MSB counter first before reading the LSB counter in order to clear the PMON count. 6 RFAEC[6] RUR 0 5 RFAEC[5] RUR 0 4 RFAEC[4] RUR 0 3 RFAEC[3] RUR 0 2 RFAEC[2] RUR 0 1 RFAEC[1] RUR 0 0 RFAEC[0] RUR 0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |