| поискавой системы для электроныых деталей |
|
LP8733 датащи(PDF) 31 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LP8733 датащи(HTML) 31 Page - Texas Instruments |
|
31 / 86 page ![]() V(VANA) VANA_UVLO State Shutdown Read OTP Standby PGOOD pin EN pin VOUT (Buck1) VOUT (LDO0) Buck1 internal powergood LDO0 internal powergood Active 800 µs Timer Buck internal enable 800 µs Timer LDO0 internal enable 4 ms 2 ms Clear fault 31 LP8733 www.ti.com SNVSBK2 – SEPTEMBER 2019 Product Folder Links: LP8733 Submit Documentation Feedback Copyright © 2019, Texas Instruments Incorporated Figure 17. PGOOD Pin Operation in Gated Mode 7.3.8.1.2 PGOOD Pin Continuous Mode The continuous (or invalid) mode of operation is selected by setting the PGOOD_MODE bit to 1 in the PGOOD_CTRL_2 register. For the continuous mode of operation, PGOOD behaves as follows: • PGOOD is set to active or asserted state upon exiting OTP configuration. • PGOOD is set to inactive or de-asserted as soon as the regulator is enabled. • PGOOD status begins indicating output voltage regulation status immediately and continuously. • During power-up sequencing and requested voltage changes, PGOOD will toggle between inactive or de- asserted while output voltages are outside of regulation ranges and active or asserted when inside of regulation ranges. The PG_FAULT register bits are latched, and maintain the fault information until the host clears the fault bit by writing 1 to the bit. The PGOOD signal also indicates a thermal shutdown and input overvoltage interrupts, which are cleared by clearing the interrupt bits. When the regulator voltage is transitioning from one target voltage to another, the PGOOD signal is set inactive. When the PGOOD signal becomes inactive, the source for the fault can be read from the PG_FAULT register. If the invalid output voltage becomes valid again, then the PGOOD signal becomes active. Thus the PGOOD signal always shows if the monitored output voltages are valid. The block diagram for this operation is shown in Figure 18 and an example of operation is shown in Figure 19. The PGOOD signal can also be configured so that it maintains an inactive state even when the monitored outputs are valid, but there are PG_FAULT_x bits in the PG_FAULT register pending clearance. This type of operation is selected by setting the PGFAULT_GATES_PGOOD bit to 1 in the PGOOD_CTRL_2 register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |