| поискавой системы для электроныых деталей |
|
VSC7511 датащи(PDF) 35 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
VSC7511 датащи(HTML) 35 Page - Microsemi Corporation |
|
35 / 324 page ![]() Functional Descriptions VMDS-10488 VSC7511 Datasheet Revision 4.2 20 (MAC_FC_CFG.FC_LATENCY_CFG). The benefit of this approach is that the queue system is not risking being overloaded with frames due to a non-complying link partner. In half-duplex mode, the MAC does not react to received pause frames. If the flow control condition is asserted by the ingress queues, the industry-standard backpressure mechanism is used. Together with the ability to retransmit frames after excessive collisions (MAC_HDX_CFG.RETRY_AFTER_EXC_COL_ENA), this enables non-dropping half-duplex flow control. 3.2.1.6 Priority-Based Flow Control (IEEE 802.1Qbb) The device supports priority-based flow control on all ports for all QoS classes. The following table lists the specific registers associated with priority-based flow control. The device provides independent support for transmission of pause frames and reaction to incoming pause frames, which allows asymmetric flow control configurations. The device obeys received pause frames per priority (ANA::PFC_CFG.RX_PFC_ENA) by pausing the egress traffic according to the timer values specified in the pause frames. Transmission of frames belonging to QoS class n is paused if bit n is set in the priority_enable_vector in the incoming pause frame. The pause time for QoS class n is given by time[n] from the pause frame. The link speed must be specified in order to evaluate the pause times (ANA::PFC_CFG.FC_LINK_SPEED). The transmission of priority-based pause frames is triggered by assertion of a flow control condition in the ingress queues caused by the memory consumption for a priority for an ingress port exceeding the BUF_Q_RSRV_I watermark. For more information about the watermark, see Table 96, page 122. The MAC handles the formatting and transmission of the priority-based pause frame. The following configuration options are available: • Transmission of priority-based pause frames per QoS class (QSYS::SWITCH_PORT-MODE.TX_PFC_ENA). • Pause timer value used in transmitted priority-based pause frames (SYS::MAC_FC_CFG.PAUSE_VAL_CFG). All congested priorities use the same pause timer value. Uncongested priorities use pause timer value 0. • Source MAC address used in transmitted priority-based pause frames (MAC_FC_MAC_HIGH_CFG, MAC_FC_MAC_LOW_CFG). • Priority protection mode (QSYS::SWITCH_PORT_MODE.TX_PFC_MODE), which enables that when a priority congests and causes a pause frame to be sent, then the pause frame will also pause all lower priorities. All transmitted priority-based pause frames have the priority_enable_vector set to 0xFF, independently of whether a priority is enabled for flow control. However, the pause timer value, time[n], is always 0 for disabled priorities. Table 7 • Priority-Based Flow Control Configuration Registers Register Description Replication SYS::MAC_FC_CFG Flow control configuration Per port DEV::MAC_FC_MAC_LOW_CFG LSB of SMAC used in pause frames Per port DEV::MAC_FC_MAC_HIGH_CFG MSB of SMAC used in pause frames Per port ANA::PFC_CFG Configuration of Rx priority-based flow control per priority. Per port QSYS:SWITCH_PORT_MODE Configuration of Tx priority-based flow control per priority Per port DEV::PORT_MISC.FWD_CTRL_ENA Enabling forwarding of priority-based pause frames to analyzer. Per port ANA::CPU_FWD_BPDU_CFG Disable forwarding of priority-based pause frames beyond the analyzer Per port |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |