| поискавой системы для электроныых деталей |
|
AD9929BBCZ датащи(PDF) 55 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9929BBCZ датащи(HTML) 55 Page - Analog Devices |
|
55 / 64 page ![]() AD9929 Rev. A | Page 55 of 64 INITIAL START-UP SEQUENCE Recommended Start-Up Sequence for Master Mode When the AD9929 is powered up, the following sequence is recommended (refer to Figure 66 for each step). 1. Turn on power supplies as described in the Power Supply Sequencing section. 2. Apply the CLI master clock input. CLI is output on DCLK2 Pin 16 at this time. 3. Reset the internal AD9929 registers. Write a 0x000000 to the SW_RESET register (Address 0x00). This sets all internal register values to their default values. (This step is optional because there is an internal power-on reset circuit that is applied at power-up.) 4. Program DIGSTBY and AFESTBY registers (Address 0x05) = 1 and all other necessary control registers. 5. Program system registers (Address 0x20). 6. Program Mode_A registers (Address 0x21). 7. Program Mode_B registers (Address 0x22). 8. Program OUTCONT_REG register (Address 0x05) = 1. (The internal OUTCONT signal is asserted high at this time. This enables the digital outputs.) 9. Program control register MODE (Address 0x0A) = 0. This selects Mode_A operation. (This step is optional because the AD9929 defaults to Mode_A at power-up.) 10. Program control register MODE (Address 0x0A) = 1. This selects Mode_B operation. Note: Complete this write at least 4 CLI cycles before the start of the next field. AD9929 POWER-UP SEQUENCE SERIAL WRITES VD (OUTPUT) 1 H ODD FIELD EVEN FIELD DIGITAL (OUTPUTS) H2, RG, MSHUT, STROBE H1, VSUB, FD HD (OUTPUT) 1 V OUTCONT1 (INTERNAL SIGNAL) DCLK1 (OUTPUT) 3 57 NOTES 1OUTCONT IS AN INTERNAL SIGNAL THAT IS CONTROLLED USING REGISTER OUTCONT_REG (ADDRESS 0x05). 2DCLK2 WILL BE OUTPUT ON THE FD/DCLK2 PIN 16 PROVIDING REGISTER DCLK2SEL (ADDRESS 0xD5) = 1. THE DCLK2SEL REGISTER DEFAULTS TO 1 AT POWER-UP. 3IT TAKES 11 CLI CLOCKS FROM WHEN OCONT GOES HIGH UNTIL VD, HD, AND DIGITAL OUTPUT DATA IS VALID. 4THERE IS A 500 µS SETTLING TIME FROM WHEN THE DIGSTBY REGISTER IS SET TO WHEN THE DCLK1 IS STABLE. ODD FIELD tSETTLING4 CLI (INPUT) DCLK22 (OUTPUT) tDELAY3 tPWR Figure 66. Recommended Start-Up Sequence and Synchronization, Master Mode |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |