Back Button MCP39F521 Datasheet HTML 14Page - Microchip Technology MCP39F521 Datasheet HTML 15Page - Microchip Technology MCP39F521 Datasheet HTML 16Page - Microchip Technology MCP39F521 Datasheet HTML 17Page - Microchip Technology MCP39F521 Datasheet HTML 18Page - Microchip Technology MCP39F521 Datasheet HTML 19Page - Microchip Technology MCP39F521 Datasheet HTML 20Page - Microchip Technology MCP39F521 Datasheet HTML 21Page - Microchip Technology MCP39F521 Datasheet HTML 22Page - Microchip Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 52 page
background image
MCP39F521
DS20005442A-page 18
 2015 Microchip Technology Inc.
TABLE 4-3:
REGISTER WRITE, N- BYTES COMMAND (Note 1)
Byte #
Value
Byte Description
Response from MCP39F521
1
0xA5
Header Byte
2
0x25
Number of Bytes in Frame
3
0x41
Command (Set Address Pointer)
4
0x00
Address High
5
0x48
Address Low
6
0x4D
Command (Register Write, N Bytes)
7
0x1C
Number of Bytes to Write (28)
8-36
*Data*
Data Bytes (28 total data bytes)
37
Checksum
Checksum
ACK
Note 1:
This Register Write, N Bytes frame, as written here, can be used to write the entire set of
calibration target data, starting at the top, address 0x7A, and continuing to write until the end of this set of
registers, 28 bytes later, register 0x94. Note these are not the calibration registers, but the calibration
targets which need to be written prior to issuing the auto-calibration target commands. See Section 8.0,
MCP39F521 Calibration
for more information.
TABLE 4-4:
SET ADDRESS POINTER COMMAND (Note 1)
Byte #
Value
Byte Description
Response from MCP39F521
1
0xA5
Header Byte
2
0x06
Number of Bytes in Frame
3
0x41
Command (Set Address Pointer)
4
0x00
Address High
50x02
Address Low
6
0xEE
Checksum
ACK
Note 1:
The Set Address Pointer command is typically included inside of a frame that includes a read or write
command, as shown in Table 4-2 and Table 4-3. There is typically no reason for this command to have its
own frame, but is shown here as an example.
TABLE 4-5:
SAVE TO FLASH COMMAND
Byte #
Value
Byte Description
Response from MCP39F521
1
0xA5
Header Byte
2
0x04
Number of Bytes in Frame
3
0x53
Command (Save To Flash)
4
0xFC
Checksum
ACK
TABLE 4-6:
PAGE READ EEPROM COMMAND
Byte #
Value
Byte Description
Response from MCP39F521
1
0xA5
Header Byte
2
0x05
Number of Bytes in Frame
3
0x42
Command (Page Read EEPROM)
4
0x01
Page Number (e.g. 1)
5
0xED
Checksum
ACK + EEPROM Page Data + Checksum



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com