| поискавой системы для электроныых деталей |
|
MCP39F521 датащи(PDF) 40 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP39F521 датащи(HTML) 40 Page - Microchip Technology |
|
40 / 52 page ![]() MCP39F521 DS20005442A-page 40 2015 Microchip Technology Inc. 3. Combine this additional phase compensation to whatever value is currently in the phase compensation, and update the register. Equation 8-9 should be computed in terms of an 8-bit two's complement signed value. The 8-bit result is placed in the least significant byte of the 16-bit Phase Compensation register. EQUATION 8-9: Based on Equation 8-9, the maximum angle in degrees that can be compensated is ±3.2 degrees. If a larger phase shift is required, contact your local Microchip sales office. 8.5 Offset/No-Load Calibrations During offset calibrations, no line voltage or current should be applied to the system. The system should be in a No-Load condition. 8.5.1 AC OFFSET CALIBRATION There are three registers associated with the AC Offset Calibration: • Offset Current RMS • Offset Active Power • Offset Reactive Power When computing the AC offset values, the respective Gain and Range registers should be taken into consideration according to the block diagrams in Figures 5-2 and 5-4. After a successful offset calibration, a Save Registers to Flash command can then be issued to save the calibration constants calculated by the device. 8.5.2 DC OFFSET CALIBRATION In DC applications, the high-pass filter on the current and voltage channels is turned off. To remove any residual DC value on the current, the DC Offset Current register adds to the A/D conversion immediately after the ADC and prior to any other function. 8.6 Calibrating the Line Frequency Register The Line Frequency register contains a 16-bit number with a value equivalent to the input line frequency as it is measured on the voltage channel. When in DC mode, this calculation is turned off and the register will be equal to zero. The measurement of the line frequency is only valid from 45 to 65 Hz. 8.6.1 USING THE AUTO-CALIBRATION FREQUENCY COMMAND By applying a stable reference voltage with a constant line frequency that is equivalent to the value that resides in the Line Frequency Ref, the Auto-Calibration Frequency command can then be issued to the device. After a successful calibration (response = ACK), a Save Registers to Flash command can then be issued to save the calibration constants calculated by the device. The following register is set when the Auto-Calibration Frequency command is issued: • Gain Line Frequency Note that the command is only required when running off the internal oscillator. The formula used to calculate the new gain is shown in Equation 8-1. PhaseCompensation NEW PhaseCompens ation OLD + = |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |