45 / 64 page ![]() 2015 Microchip Technology Inc. DS20005424B-page 45 UCS2112 9.3 Configuration Registers The Configuration registers control basic device functionality. The contents of these registers are retained in Sleep. REGISTER 9-7: GENERAL CONFIGURATION 1 REGISTER (ADDRESS 11H) R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-1 R/W-1 R/W-0 ALERT1_MASK ALERT1_LINK DSCHG1 PWR_EN1S DISCHG_TIME<1:0> ATT_TH1<1:0> bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit C = Clear on Read -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 7 ALERT1_MASK: Mask errors for all interrupts in Register 9-3 except OV_LIM1 and TSD. 1 = The ALERT#1 pin will only assert if a OV_LIM1 or TSD is detected. 0 = The ALERT#1 pin will be asserted if an error condition or indicator event is detected. bit 6 ALERT1_LINK: Links the ALERT#1 pin to be asserted when the LOW_CUR1 bit is set. 1 = The ALERT#1 pin will be asserted if the LOW_CUR1 indicator bit is set. 0 = The ALERT#1 pin will not be asserted if the LOW_CUR1 indicator bit is set. bit 5 DSCHG1: Forces the VBUS1 to be reset and discharged when the UCS2112 is in the Active state. Writing this bit to a logic ‘1’ will cause the port power switch to be opened and the discharge circuitry to activate and discharge VBUS. Actual discharge time is controlled by DISCHG_TIME<1:0>. This bit is self-clearing. 1 =VBUS1 discharge initiated. 0 = Port 1 not in discharge bit 4 PWR_EN1S: Power Enable Port 1 override - This bit is OR’ed with the PWR_EN1 pin. Thus, if the polarity is set to active-high, either the PWR_EN1 pin or this bit must be ‘1’ to enable the port power switch. bit 3-2 DISCHG_TIME<1:0>: Discharge time Port 1 - sets tDISCHARGE. The discharge time value is the same for both ports. 00 = 100 ms 01 = 200 ms 10 = 300 ms 11 = 400 ms bit 1-0 ATT_TH1<1:0>: Attach Detection Threshold Port 1 - determines the current draw needed to deter- mine an Attach event has occurred. Also controls the Removal Detection current level (Note 1). 00 = 200 µA Attach/100 µA Removal 01 = 400 µA Attach/300 µA Removal 10 = 800 µA Attach/700 µA Removal 11 = 1000 µA Attach/900 µA Removal Note 1: The removal threshold is different when operating in the Active power state versus when operating in the Detect power state. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |