UCS2112 датащи(PDF) 30 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS2112 датащи(HTML) 30 Page - Microchip Technology |
|
30 / 64 page ![]() UCS2112 DS20005424B-page 30 2015 Microchip Technology Inc. 7.3 Thermal Management and Voltage Protection 7.3.1 THERMAL MANAGEMENT The UCS2112 utilizes two-stage internal thermal man- agement. The first stage is Dynamic Thermal Manage- ment, and the second stage is Fixed Thermal Shutdown. 7.3.1.1 Dynamic Thermal Management For the first stage (active in both current-limiting modes), referred to as Dynamic Thermal Manage- ment, the UCS2112 automatically adjusts port power switch limits and modes to lower power dissipation when the thermal regulation temperature value is approached, as described in the following paragraphs. If the internal temperature exceeds the TREG value, the port power switch is opened, the current limit (ILIM) will be lowered by one step and a timer is started (tDC_TEMP). When this timer expires, the port power switch is closed and the internal temperature will be checked again. If it remains above the TREG threshold, the UCS2112 will repeat this cycle (open port power switch and reduce the ILIM setting by one step) until ILIM reaches its minimum value. If the UCS2112 is operating using Constant Current Limiting (variable slope) and the ILIM setting has been reduced to its minimum set point and the temperature is still above TREG, the UCS2112 will switch to operat- ing using trip current limiting. This will be done by reducing the IBUS_R2MIN setting to 100 mA and restor- ing the ILIM setting to the value immediately below the programmed setting (e.g., if the programmed ILIM is 2.13A, the value will be set to 1.6A). If the temperature continues to remain above TREG, the UCS2112 will continue this cycle (open the port power switch and reduce the ILIM setting by one step). If the UCS2112 internal temperature drops below TREG - TREG_HYST, the UCS2112 will take action based on the following: 1. If the Current Limit mode changed from CC mode to Trip mode, then a timer is started. When this timer expires, the UCS2112 will reset the port power switch operation to its original configuration, allowing it to operate using Con- stant Current Limiting (variable slope). 2. If the Current Limit mode did not change from CC mode to Trip mode, or was already operating in Trip mode, the UCS2112 will reset the port power switch operation to its original configuration. If the UCS2112 is operating using Trip Current Limiting and the ILIM setting has been reduced to its minimum set point and the temperature is above TREG, the port power switch will be closed and the current limit will be held at its minimum setting until the temperature drops below TREG - TREG_HYST. 7.3.1.2 Thermal Shutdown The second stage of thermal management consists of a hardware implemented thermal shutdown corre- sponding to the maximum allowable internal die tem- perature (TTSD). If the internal temperature exceeds this value, the port power switches (both ports) will immediately be turned off until the temperature is below TTSD -TTSD_HYST. 7.4 VBUS Discharge The UCS2112 will discharge VBUS through an internal 100 resistor when at least one of the following condi- tions occurs: • The PWR_EN control is disabled (triggered on the inactive edge of the PWR_EN control). • A portable device Removal Detection event is flagged if the Attach/Removal Detect feature is enabled (by default it is disabled). •The VS voltage drops below a specified threshold (VS_UVLO) that causes the port power switch to be disabled. • When commanded into the Sleep power state. • Upon recovery from the Error state. • When commanded via the SMBus in the Active state. • Any time the port power switch is activated after the VBUS bypass switch has been on (i.e., when- ever VBUS voltage transitions from being driven from VDD to being driven from VS, such as going from Detect to Active power state) if the Attach/Removal Detect feature is enabled (by default it is disabled). • Any time the VBUS bypass switch is activated after the port power switch has been on (i.e., going from Active to Detect power state) if the Attach/Removal Detect feature is enabled (by default it is disabled). When the VBUS discharge circuitry is activated at the end of the tDISCHARGE time, the UCS2112 will confirm that VBUS was discharged. If the VBUS voltage is not below the VTEST level, a discharge error will be flagged (by setting the DISCH_ERR(1/2) status bit) and the UCS2112 will enter the Error state. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |