| поискавой системы для электроныых деталей |
|
HM17CM256 датащи(PDF) 60 Page - Hynix Semiconductor |
|
|
|||||||||||||||||||||||||||||
HM17CM256 датащи(HTML) 60 Page - Hynix Semiconductor |
|
60 / 111 page ![]() HM17CM256 - 60 - (34-10) Power control register set CS RS RD WR RE2 RE1 RE0 D7 D6 D5 D4 D3 D2 D1 D0 0 1 1 0 0 0 0 1 0 1 1 AMPON HALT DCON ACL ( reset :{AMPON, HALT, DCON, ACL}=0H read address :BH ) a) ACL command This command initializes internal circuit and it is valid only at master operating. ACL=”0”: normal state ACL=”1”: initialization ON Just after the execution of ACL command (ACL=”1”), D0 bit is set to 1. But as the initialization process goes on internally, D0 is reset to “0”. When ACL command is executed, internal reset signal is produced by using local display clock ( clock from internal oscillator or from external resistor oscillation mode ). So, after ACL command is executed, it needs to WAIT at least 2 period of the clock for next process beginning. ACL command is effective only at master mode operation because it uses original oscillator clock. It is prohibited for slave mode operation to use the internal oscillator or external oscillator. So, ACL command is impossible at slave mode. Please reset the slave device at RES terminal, when needed. b) DCON command ON/OFF the internal voltage boosting circuit. DCON=”0”: boosting circuit OFF DCON=”1”: boosting circuit ON c) HALT command Power save mode ON/OFF control HALT=”0”: normal state HALT=”1”: power save state The power consumption is decreased near static current at power save mode. States of each sub-block in power save mode are as follow. • Oscillator, built-in power supply block stop. • Stop driving LCD panel, segment drive, the outputs of common driver are all set to V SS level. • Clock input from OSC 1 port is disabled. • Display RAM data are conserved. • Operational modes are preserved as those before power save command was executed. • V LCD, V1 ~ V4 become high impedance state. Make display OFF state before power save mode by HALT command. And when returning from power save mode, you should display ON after oscillator, power circuit is activated stably. After display OFF and HALT command, if the display is turned ON before oscillator and power circuit is not activated stably, wrong display can be appeared. d) AMPON command ON/OFF the internal OP. amplifier circuit of power block (voltage regulator block, electric volume, voltage converting circuit ). AMPON=”0”: internal power circuit OP. Amplifier OFF AMPON=”1”: internal power circuit OP. Amplifier ON |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |