47 / 92 page ![]() www.austriamicrosystems.com Revision 1.11 46 - 91 AS3543 3v2 Data Sheet - D e t a i l e d D e s c r i p t i o n - S Y S T E M F u n c t i o n s 10.3 Supervisor 10.3.1 General This supervisor function can be used for automatic detection of BVDD brown out or junction over-temperature condi- tion. 10.3.2 BVDD Supervision The BVDD supervision interrupt level is set to 175mV above regulator output AVDD27. When BVDD reaches this level an interrupt can be generated. If AVDD27 reaches the “programmed level of AVDD27” -10% for more than 680us, the AFE shuts down automatically, if the shutdown is not disabled. 10.3.3 Junction Temperature Supervision The temperature supervision level can also be set by 5 bits (120 to –15ºC). If the temperature reaches this level, an interrupt can be generated. The over-temperature shutdown level is always 20ºC higher. 10.3.4 Power Rail Monitoring The 4 main regulators as well as the DCDC15 booster and the system supply AVDD27 have an extra monitor which observes the output voltage of the regulators. This power rail monitors are independent from the 10bit ADC. To activate these please see related registers. For a shut down the voltage of the regulator has to be 10% or more below the pro- grammed value for more than 680us. 10.3.5 Register Description 10.4 Interrupt Generation 10.4.1 General All interrupt sources can get enabled or disabled by corresponding bits in the 5 IRQ-bytes. By default no interrupt source is enabled. The XIRQ output can be configured to operate in push/pull (2 different driver strengths), open-drain mode or to be tri- state. The signal polarity can be defined as active-low or active-high. Default state is open-drain active-low. For a more detailed description of the GPIO functionality of this pin please refer to chapter GPIO Pins on page 50. 10.4.2 IRQ Source Interpretation There are 3 different modules to process interrupt sources: LEVEL The IRQ output is kept active as long as the interrupt source is present and this IRQ-Bit is enabled EDGE The IRQ gets active with a high going edge of this source. The IRQ stays active until the corresponding IRQ-Register gets read. Table 34. Supervisor Related Register Name Base Offset Description SUPERVISOR 2-wire serial 21h Low battery shutdown disable and junction temperature supervision threshold levels IRQENRD_0 2-wire serial 23h Enable/disable PVDD/CVDD monitoring interrupt and shutdown IRQENRD_1 2-wire serial 24h Enable/disable PVDD/CVDD monitoring interrupt and shutdown IRQENRD_2 2-wire serial 25h Enable/disable battery brown out interrupt IRQENRD_3 2-wire serial 26h Enable/disable junction temperature interrupt IRQENRD_4 2-wire serial 27h Enable/disable AVDD27 and DCDC15 monitoring interrupt |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |