74 / 81 page ![]() C167CS-4R C167CS-L Data Sheet 70 V2.2, 2001-08 Bus Cycle Control via READY Input The duration of an external bus cycle can be controlled by the external circuitry via the READY input signal. Synchronous READY permits the shortest possible bus cycle but requires the input signal to be synchronous to the reference signal CLKOUT. Asynchronous READY puts no timing constraints on the input signal but incurs one waitstate minimum due to the additional synchronization stage. Notes (Valid for Table 19 and Figure 21) 1) Cycle as programmed, including MCTC waitstates (Example shows 0 MCTC WS). 2) Multiplexed bus modes have a MUX waitstate added after a bus cycle, and an additional MTTC waitstate may be inserted here. For a multiplexed bus with MTTC waitstate this delay is 2 CLKOUT cycles, for a demultiplexed bus without MTTC waitstate this delay is zero. 3) These timings are given for test purposes only, in order to assure recognition at a specific clock edge. If the Asynchronous READY signal does not fulfill the indicated setup and hold times with respect to CLKOUT, it must fulfill tc27 in order to be safely synchronized. Proper deactivation of READY is guaranteed if READY is deactivated in response to the trailing (rising) edge of the corresponding command (RD or WR). 4) READY sampled HIGH at this sampling point generates a READY controlled waitstate, READY sampled LOW at this sampling point terminates the currently running bus cycle. 5) If the next following bus cycle is READY controlled, an active READY signal must be disabled before the first valid sample point for the next bus cycle. This sample point depends on the MTTC waitstate of the current cycle, and on the MCTC waitstates and the ALE mode of the next following cycle. If the current cycle uses a multiplexed bus the intrinsic MUX waitstate adds another CLKOUT cycle to the READY deactivation time. Table 19 READY Timing (Operating Conditions apply) Parameter Symbol Limit Values Unit min. max. Input setup time to CLKOUT rising edge Valid for: READY input tc25 CC 12 – ns Input hold time after CLKOUT rising edge Valid for: READY input tc26 CC 0 – ns Asynchronous READY input low time3) tc27 CC tc5 + tc25 – ns |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |