87 / 293 page ![]() uPSD34xx Standard 8032 timer/counters 87/293 20 Standard 8032 timer/counters There are three 8032-style 16-bit Timer/Counter registers (Timer 0, Timer 1, Timer 2) that can be configured to operate as timers or event counters. There are two additional 16-bit Timer/Counters in the Programmable Counter Array (PCA), see Section 27.1: PCA block on page 175 for details. 20.1 Standard timer SFRs Timer 0 and Timer 1 have very similar functions, and they share two SFRs for control: ● TCON (Table 41 on page 88) ● TMOD (Table 42 on page 90). Timer 0 has two SFRs that form the 16-bit counter, or that can hold reload values, or that can scale the clock depending on the timer/counter mode: ● TH0 is the high byte, address 8Ch ● TL0 is the low byte, address 8Ah Timer 1 has two similar SFRs: ● TH1 is the high byte, address 8Dh ● TL1 is the low byte, address 8Bh Timer 2 has one control SFR: ● T2CON (Table 43 on page 93) Timer 2 has two SFRs that form the 16-bit counter, and perform other functions: ● TH2 is the high byte, address CDh ● TL2 is the low byte, address CCh Timer 2 has two SFRs for capture and reload: ● RCAP2H is the high byte, address CBh ● RCAP2L is the low byte, address CAh 20.2 Clock sources When enabled in the “Timer” function, the Registers THx and TLx are incremented every 1/12 of the oscillator frequency (fOSC). This timer clock source is not effected by MCU clock dividers in the CCON0, stalls from PFQ/BC, or bus transfer cycles. Timers are always clocked at 1/12 of fOSC. When enabled in the “Counter” function, the Registers THx and TLx are incremented in response to a 1-to-0 transition sampled at their corresponding external input pin: pin C0 for Timer 0; pin C1 for Timer 1; or pin T2 for Timer 2. In this function, the external clock input pin is sampled by the counter at a rate of 1/12 of fOSC. When a logic '1' is determined in one sample, and a logic '0' in the next sample period, the count is incremented at the very next sample period (period1: sample=1, period2: sample=0, period3: increment count while continuing to sample). This means the maximum count rate is 1/24 of the fOSC. There are no restrictions on the duty cycle of the external input signal, but to ensure that a given level is sampled at least once before it changes, it should be active for at least one full sample |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |