| поискавой системы для электроныых деталей |
|
INA700 датащи(PDF) 18 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
INA700 датащи(HTML) 18 Page - Texas Instruments |
|
18 / 50 page ![]() Number of Conversions 0 2000 4000 6000 8000 10000 Conversion Time: 50 µs Conversion Time: 1.052 ms Conversion Time: 4.120 ms Figure 7-9. Noise vs Conversion Time (Averaging = 128) Settings for the conversion time and number of conversions averaged impact the effective measurement resolution. See ADC Output Data Rate and Noise Performance for more detailed information on how averaging reduces noise and increases the effective number of bits (ENOB). 7.3.6 Integrated Precision Oscillator The internal timebase of the device is provided by an internal oscillator that is trimmed to less than 0.5% tolerance at room temperature. The precision oscillator is the timing source for ADC conversions, as well as the time-count used for calculation of energy and charge. The digital filter response varies with conversion time; therefore, the precise clock provides filter response and notch frequency consistency across temperature. On power up, the internal oscillator and ADC take roughly 300 µs to reach <1% error stability. After the clock stabilizes, the ADC data output will be accurate to the electrical specifications provided in Specifications. 7.3.7 Multi-Alert Monitoring and Fault Detection The INA700 includes a multipurpose, open-drain, ALERT output pin that can be used to report multiple diagnostics or as an indicator that the ADC conversion is complete when the device is operating in both triggered and continuous conversion mode. The diagnostics listed in Table 7-1 are constantly monitored and can be reported through the ALERT pin whenever the monitored output value crosses the associated out-of-range threshold. Table 7-1. ALERT Diagnostics Description INA700 DIAGNOSTIC STATUS BIT IN ALERT_DIAG REGISTER (READ ONLY) OUT-OF-RANGE THRESHOLD REGISTER (R/W) REGISTER DEFAULT VALUE Current Under-Limit CURRENTUL CUL 0x8000 h (2's complement)) Current Over-Limit CURRENTOL COL 0x7FFF h (2's complement)) Bus Voltage Over-Limit BUSOL BOVL 0x7FFF h (2's complement), positive values only) Bus Voltage Under-Limit BUSUL BUVL 0x0000 h (2's complement), positive values only) Temperature Over-Limit TMPOL TEMP_LIMIT 0xFFFF h (2's complement), positive values only) Power Over-Limit POL PWR_LIMIT 0x7FFF h (2's complement)) INA700 SBOSAB4A – MAY 2023 – REVISED SEPTEMBER 2023 www.ti.com 18 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: INA700 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |