| поискавой системы для электроныых деталей |
|
INA700 датащи(PDF) 36 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
INA700 датащи(HTML) 36 Page - Texas Instruments |
|
36 / 50 page ![]() An overcurrent threshold is set by programming the Current Over-Limit Threshold register (COL). The value that must be programmed into this register is calculated by dividing the overcurrent limit value by the current LSB size. For this example, the target value for the COL register is 9 A ÷ 480 μA = 18750d (493Eh). An overvoltage fault threshold on the bus voltage is set by programming the bus overvoltage limit register (BOVL). In this example the desired overvoltage threshold is 14 V. The value that must be programmed into this register is calculated by dividing the target threshold voltage by the bus voltage fault limit LSB value of 3.125 mV. For this example, the target value for the BOVL register is 14 V ÷ 3.125 mV = 4480d (1180h). When setting the power over-limit value, the LSB size used to calculate the value needed in the limit registers will be 256 times greater than the power LSB. This is because the power register is a 24 bits in length while the power fault limit register is 16 bits. The LSB value to use for setting the over-power fault limit is 24.576 mW. Values stored in the alert limit registers are set to the default values after VS power cycle events and must be reprogrammed each time power is applied. 8.2.2.3 Calculate Returned Values Parametric values are calculated by multiplying the returned value by the LSB value. Table 8-4 shows the returned values for this application example, assuming the design requirements shown in Table 8-3. Table 8-4. Calculating Returned Values PARAMETER RETURNED VALUE LSB VALUE CALCULATED VALUE Current (A) 10417d 480 µA 5.00016 A Bus voltage (V) 3840d 3.125 mV 12 V Power (W) 625020d 96 µW 60.00192 W Energy (J) 140629500d 1.536 mJ 216.007 kJ Charge (C) 3750120d 30 µC 18000.576 C Temperature (°C) 320d 125 mºC 40°C Current, Bus Voltage (positive only), Charge, and Temperature return values in 2's-complement format. In 2's-complement format a negative value in binary is represented by having a 1 in the most significant bit of the returned value. These values can be converted to decimal by first inverting all the bits and adding 1 to obtain the unsigned binary value. This value can then be converted to decimal with the negative sign applied. For example, assume a current reading returns 1011 0100 0001 0000. This is a negative value due to the MSB having a value of one. Inverting the bits and adding one results in 0100 1011 1111 0000 (19440d) which from the current value example in Table 8-4 correlates to a current of 9.3312 A. The returned value was negative, therefore the measured current value is –9.3312 A. INA700 SBOSAB4A – MAY 2023 – REVISED SEPTEMBER 2023 www.ti.com 36 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: INA700 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |