| поискавой системы для электроныых деталей |
|
ZAMC4100 датащи(PDF) 53 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZAMC4100 датащи(HTML) 53 Page - Renesas Technology Corp |
|
53 / 156 page ![]() ZAMC4100 Datasheet © 2016 Integrated Device Technology, Inc. 53 January 26, 2016 Table 3.9 IRQSTAT Register Bits Mapping Name IRQSTAT 1) Bit No 7 6 5 4 3 2 1 0 Bit name Reset 0 0 0 0 0 0 0 0 Access R R R R R R R R Address 0x01 R = Read-only bit 1) The ECMOCIF is physically implemented in register ECMDIAG (Table 3.30) and mapped to IRQSTAT. Table 3.10 IRQSTAT Register Bits Description Bit Description 7 WDTIF: WDT interrupt flag. 1 = Watchdog timer time-out occurred during STANDBY Mode. 0 = Watchdog timer interrupt did not occur. Note: In order to clear WDTIF, the MCU must clear the WDT by toggling the WDTCLR bit (see Table 3.4). 6 OVTIF: Over-temperature interrupt flag. 1 = Over-temperature event occurred. 0 = Over-temperature event did not occur. Note: In order to clear OVTIF, the MCU should clear the OVTF flag in register RSTSTAT (Table 3.1). 5 SEIF: Supply error interrupt flag. 1 = The system supply voltage is out of range. There was an overvoltage or under-voltage event, and as a result, one of the flags OVIF or UVIF is set. 0 = A supply error interrupt has not occurred. The supply voltage is in range. Note: The SEIF cannot be directly cleared. In order to clear SEIF, the MCU should clear the CPVEIF, OVIF, and UVIF flags in the RSTSTAT register. 4 ADCIF: ADC global interrupt flag. 1 = ADC interrupt occurred. The ADC conversion is ready or the comparator threshold has been reached. 0 = ADC interrupt did not occur. Note: The ADCIF interrupt flag cannot be directly cleared. ADCIF is cleared by clearing the correlated ADCRDYIF or ADCCMPIF flags in the ADCSTAT register (Table 3.39). 3 HBOCIF: Half-bridge driver over-current global interrupt flag. 1 = An over-current event was detected in one or more of the half-bridge drivers. To determine the specific over- current source, the MCU should read the HBxOCIF bits in the HBDSTAT register (Table 3.15). 0 = A half-bridge driver over-current event was not detected. Note: The HBOCIF interrupt flag cannot be directly cleared. In order to clear HBOCIF, the MCU should clear the HBxOCIF flags in the HBDSTAT register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |