| поискавой системы для электроныых деталей |
|
ACT5880 датащи(PDF) 29 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT5880 датащи(HTML) 29 Page - Active-Semi, Inc |
|
29 / 87 page ![]() ACT5880 Rev 2, 03-Sep-13 - 29 - www.active-semi.com ActivePMU TM and ActivePathTM are trademarks of Active-Semi. I2CTM is a trademark of NXP. Copyright © 2013 Active-Semi, Inc. Active-Semi Confidential―Do Not Copy or Distribute REGISTER AND BIT DESCRIPTIONS CONT’D BLOCK ADDRESS and BIT NAME DEFAULT and ACCESS DESCRIPTION ODO3 0x76 7 ISCALE3[1] 0 W/R Set the LSB weight of the linear current setting of the open- drain driver. [1:0]=00 for 0.4mA, 01 for 0.8mA, 10 for 1.2mA, 11 for 1.6mA. 6 ISCALE3[0] 0 5 ISET3[5] 0 W/R Driver output current setting in linear code, no offset. [ 5:0]=0 for 0mA output. Full scale output currents are 25.2mA, 50.4mA, 75.6mA and 100.8mA respectively with different LSB weights. 4 ISET3[4] 0 3 ISET3[3] 0 2 ISET3[2] 0 1 ISET3[1] 0 0 ISET3[0] 0 0x77 7 DUTY3[7] 0 W/R PWM duty setting. [7:0]=0x00 for 0%, [7:0]=0xFF for 100%. For linear duty setting option, the LSB weight is 0.4% for code 0x00 to 0xFE, which is 0% to 99.2% of duty. The code 0xFF is forced for 100% duty. For the non-linear duty setting option, refer to the table of NON- LINEAR DUTY SETTING for code to duty cross. 6 DUTY3[6] 0 5 DUTY3[5] 0 4 DUTY3[4] 0 3 DUTY3[3] 0 2 DUTY3[2] 0 1 DUTY3[1] 0 0 DUTY3[0] 0 ODO 0x79 7 THERMAL_OK 1 R Driver circuit over temperature indicator. This bit is cleared to 0 if the driver circuit over temperature happens. 6 OK1 0 5 OK2 0 R Indicator for ODO2 out current of regulation (open LED de- tected). 4 OK3 0 3 RFU 1 2 RFU 0 1 RFU 0 0 BUFFER 0 R R R W/R W/R W/R Indicator for ODO1 out current of regulation (open LED de- tected). Indicator for ODO3 out current of regulation (open LED de- tected). Reserved for future use. Reserved for future use. Reserved for future use. Set 1 to select data buffers. Buffered data is updated to each output simultaneously when this bit is cleared to 0, for synchro- nized output. Note: W/R: Write and read accessible. R: Read accessible, writing to the bit does not make change to the volume. WE/R: Write and read accessible, write exact what it is before to avoid unexpected behavior. X is uncertain volume. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |