| поискавой системы для электроныых деталей |
|
ACT5880 датащи(PDF) 20 Page - Active-Semi, Inc |
|
|
|||||||||||||||||||||||||||||
ACT5880 датащи(HTML) 20 Page - Active-Semi, Inc |
|
20 / 87 page ![]() ACT5880 Rev 2, 03-Sep-13 - 20 - www.active-semi.com ActivePMU TM and ActivePathTM are trademarks of Active-Semi. I2CTM is a trademark of NXP. Copyright © 2013 Active-Semi, Inc. Active-Semi Confidential―Do Not Copy or Distribute REGISTER AND BIT DESCRIPTIONS CONT’D BLOCK ADDRESS and BIT NAME DEFAULT and ACCESS DESCRIPTION REG1 0x10 7 x 0 W/R For internal use only. 6 x 0 W/R 5 VSET0[5] 0 W/R Voltage Setting for the REG1 output when VSEL=0. Default set- ting is 1.2V. Refer to the STEP-DOWN DC/DC AND LDO OUT- PUT VOLTAGE SETTING table for details. 4 VSET0[4] 1 W/R 3 VSET0[3] 1 W/R 2 VSET0[2] 0 1 VSET0[1] 0 0 VSET0[0] 0 0x11 7 x 0 W/R 6 x 0 W/R 5 VSET1[5] 0 W/R Voltage Setting for the REG1 when VSEL=1. Default setting is 1.2V (This voltage setting is also known as "Standby Voltage"). Refer to the STEP-DOWN DC/DC AND LDO OUTPUT VOLT- AGE SETTING table for details. 4 VSET1[4] 1 W/R 3 VSET1[3] 1 W/R 2 VSET1[2] 0 1 VSET1[1] 0 0 VSET1[0] 0 0x12 7 ON 1 W/R Regulator On/Off Bit. Set bit to 1 to turn on the regulator, set bit to 0 to turn off the regulator. 6 PHASE 0 W/R Regulator Phase Control. Set bit to 1 for the regulator to operate 180° out of phase with the oscillator, set bit to 0 for the regulator to operate in phase with the oscillator. 5 MODE 0 W/R Regulator Mode Select. Set bit to 1 for fixed-frequency PWM mode under all load conditions, set bit to 0 to allow PFM mode under light-load conditions. 4 DELAY[2] 0 W/R Regulator Turn-on Delay Control. DELAY[2:0]=000 for no delay. Other code to delay relationship: 001 for 2ms, 010 for 4ms, 011 for 8ms, 100 for 16ms, 101 for 32ms, 110 for 64ms and 111 for 128ms. There is a propagation delay for about 100μs if selecting no delay. 3 DELAY[1] 0 2 DELAY[0] 0 1 nFLTMSK 0 W/R Regulator Fault Interrupt Mask. Set bit to 1 to enable fault- interrupt when the output is out of regulation, set bit to 0 to dis- able fault-interrupt. 0 OK R R Regulator Power-OK Status. Value is 0 when the output is out of regulation, value is 1 when the output is in regulation. For internal use only. Note: W/R: Write and read accessible. R: Read accessible, writing to the bit does not make change to the volume. WE/R: Write and read accessible, write exact what it is before to avoid unexpected behavior. X is uncertain volume. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |