| поискавой системы для электроныых деталей |
|
AMC7812SPAPR датащи(PDF) 70 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
AMC7812SPAPR датащи(HTML) 70 Page - Texas Instruments |
|
70 / 92 page ![]() AMC7812 SBAS513E – JANUARY 2011 – REVISED SEPTEMBER 2013 www.ti.com Table 22. Status Register BIT NAME DEFAULT R/W DESCRIPTION 15 — 0 R Reserved. Writing to this bit causes no change. Reading this bit returns '0'. CH0-ALR = '1' when single-ended channel 0 or differential input pair (CH0+/CH1–) is out of 14 CH0-ALR 0 R the range defined by the corresponding threshold registers. CH0-ALR = '0' when the analog input is not out of the specified range. CH1-ALR = '1' when single-ended channel 1 is out of the range defined by the 13 CH1-ALR 0 R corresponding threshold registers. CH1-ALR = '0' when the analog input is not out of the specified range. CH2-ALR = '1' when single-ended channel 2 or differential input pair (CH2+/CH3–) is out of 12 CH2-ALR 0 R the range defined by the corresponding threshold registers. CH2-ALR = '0' when the analog input is not out of the specified range. CH3-ALR = '1' when single-ended channel 3 is out of the range defined by the 11 CH3-ALR 0 R corresponding threshold registers. CH3-ALR = '0' when the analog input is not out of the specified range. Local temperature under-range flag. LT-Low-ALR = '1' when the local temperature is less than the low-bound threshold. 10 LT-Low-ALR 0 R LT-Low-ALR = '0' when the local temperature is not less than the range. This bit is only checked when LT is enabled (EN-LT = '1'); it is ignored when EN-LT = '0'. Local temperature over-range flag. LT-High-ALR = '1' when the local temperature is greater than the high-bound threshold. 9 LT-High-ALR 0 R LT-High-ALR = '0' when the local temperature is not greater than the range. This bit is only checked when LT is enabled (EN-LT = '1'); it is ignored when EN-LT = '0'. Remote temperature reading of D1when less than the range flag. D1-Low-ALR = '1' when the local temperature is less than the low-bound threshold. 8 D1-Low-ALR 0 R D1-Low-ALR = '0' when the local temperature is not less than the range. This bit is only checked when D1 is enabled (EN-D1 = '1'); it is ignored when EN-D1 = '0'. Remote temperature reading of D1 when greater than the range flag. D1-High-ALR = '1' when the local temperature is greater than the high-bound threshold. 7 D1-High -ALR 0 R D1-High-ALR = '0' when the local temperature is not greater than the range. This bit is only checked when D1 is enabled (EN-D1 = '1'); it is ignored when EN-D1 = '0'. Remote temperature reading of D2 when less than the range flag. D2-Low-ALR = '1' when the local temperature is less than the low-bound threshold. 6 D2-Low-ALR 0 R D2-Low-ALR = '0' when the local temperature is not less than the range. This bit is only checked when D2 is enabled (EN-D2 = '1'); it is ignored when EN-D2 = '0'. Remote temperature reading of D2 when greater than the range flag. D2-High-ALR = '1' when the local temperature is greater than the high-bound threshold. 5 D2-High -ALR 0 R D2-High-ALR = '0' when the local temperature is not greater than the range. This bit is only checked when D2 is enabled (EN-D2 = '1'); it is ignored when EN-D2 = '0'. Remote sensor D1 failure flag. D1-FAIL-ALR = '1' when the sensor is an open-circuit or short-circuit. 4 D1-FAIL-ALR 0 R D1-FAIL-ALR = '0' when the sensor is in a normal condition. This bit is only checked when D1 is enabled (EN-D1 = '1'); it is ignored when EN-D1 = '0'. Remote sensor D2 failure flag. D2-FAIL-ALR = '1' when the sensor is an open-circuit or short-circuit. 3 D2-FAIL-ALR 0 R D2-FAIL-ALR = '0' when the sensor is in a normal condition. This bit is only checked when D2 is enabled (EN-D2 = '1'); it is ignored when EN-D2 = '0'. Thermal alarm flag. When the die temperature is equal to or greater than +150°C, the bit is set ('1') and the THERM-ALR flag activates. The on-chip temperature sensor (LT) monitors 2 THERM-ALR 0 R the die temperature. If LT is disabled, the THERM-ALR bit is always '0'. The hysteresis of this alarm is 8°C. 1 — 0 R Reserved. Writing to this bit causes no change. Reading this bit returns '0'. 0 — 0 R Reserved. Writing to this bit causes no change. Reading this bit returns '0'. 70 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated Product Folder Links: AMC7812 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |