| поискавой системы для электроныых деталей |
|
13892 датащи(PDF) 80 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
13892 датащи(HTML) 80 Page - Freescale Semiconductor, Inc |
|
80 / 156 page ![]() Analog Integrated Circuit Device Data 80 Freescale Semiconductor 13892 FUNCTIONAL DEVICE OPERATION SUPPLIES When configured for SID mode, a high pulse on the DVSx pin will indicate one of 3 actions to take, with the decoding as a function of how many contiguous SPI clock falling edges are seen while the DVSx pin is held high. Table 51. SID Control Protocol 0 No action. Switcher stays at its presently programmed configuration 1 Jog down. Drive buck switcher output down a single DVS step 2 Jog up. Drive buck switcher output up a single DVS step 3 or more Panic Mode. DVS step the buck switcher output to the Normal mode value as programmed in the SPI register The SID protocol is illustrated by way of example, assuming SIDEN = 1, and that DVS1 is controlling SW1. SW1 starts out at its default value of 1.250 V (SW1 = 11010) and is stepped both up and down via the DVS1 pin. The SPI bits SW1 = 11010 do not change. The set point adjustment takes place in the SID block prior to bit delivery to the switcher's digital control. SW1 output DVS1 SPICLK Up Down 1.250 1.275 1.250 Down 1.225 Starting Value DVS Up DVS Down DVS Down 12 1 1 SPICLK shut down when not used Figure 21. SID Control Example for Increment & Decrement SID Panic Mode is provided for rapid recovery to the programmed Normal mode output voltage, so the processor can quickly recover to its high performance capability with a minimum of communication latency. In Figure 22, Panic Mode recovery is illustrated as an Increment step, initiated by the detection of the second falling SPI clock edge, followed by a continuation to the programmed SW1[4:0] level (1.250 V in this example), due to the detection of the third contiguous falling edge of SPI clock while DVS1 is held high. SW1 output DVS1 SPICLK Up 1.050 Starting Value DVS Up SID Panic Mode Example Panic DVS step all the way back to 1.250V (SW1[4:0] programmed value = 1.250V) 3 12 SPICLK shut down when not used Figure 22. SID Control Example for Panic Mode Recovery The system will not respond to a new jog command until it has completed a DVS step that may be in progress. Any missed jog requests will not be stored. For instance, if a switcher is stepping up in voltage with a 25 mV step over a 4.0 μs time, response to the DVSx pin for another step will be ignored until the DVS step period has expired. However, the Panic Mode step recovery should respond immediately upon detection of the third SPICLK edge while the corresponding DVSx pin is high, even if the initial decode of the jog up command is ignored, because it came in before the previous step was completed. Number of SPI CLK Falling Edges while DVSx = 1 Function |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |