| поискавой системы для электроныых деталей |
|
TSB41BA3DIPFP датащи(PDF) 15 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TSB41BA3DIPFP датащи(HTML) 15 Page - Texas Instruments |
|
15 / 59 page ![]() RECOMMENDED OPERATING CONDITIONS TSB41BA3D www.ti.com ............................................................................................................................................... SLLS959A – DECEMBER 2008 – REVISED MARCH 2009 MIN TYP(1) MAX UNIT Source power node 3 3.3 3.6 Supply voltage, 3.3 VDD V Nonsource power node 3(2) 3.3 3.6 TSB41BA3D 1.7 1.85 2 Supply voltage, 1.8 VDD V TSB41BA3DI 1.75 1.85 2 LREQ, CTL0, CTL1, D0–D7, LCLK_PMC 2.6 S5_LKON, S4, S3, S2_PC0, S1_PC1, S0_PC2, High-level input voltage, VIH SLPEN, PD, BMODE, TPBIAS0_SD0, TPBIAS1_SD1, 0.7 VDD V TPBIAS2_SD2 RESET 0.6 VDD LREQ, CTL0, CTL1, D0–D7, LCLK_PMC 1.2 S5_LKON, S4, S3, S2_PC0, S1_PC1, S0_PC2, Low-level input voltage, VIL SLPEN, PD, BMODE, TPBIAS0_SD0, TPBIAS1_SD1, 0.2 VDD V TPBIAS2_SD2 RESET 0.3 VDD Output current, IOL/OH CTL0, CTL1, D0–D7, S5_LKON, PINT, PCLK –4 4 mA Output current, IO TPBIAS outputs –5.6 1.3 mA RθJA = 19°C/W, TA = 70°C 84.1 RθJA = 31.5°C/W, TA = 70°C 93.3 Maximum junction temperature, TJ RθJA = 49.2°C/W, TA = 70°C 106.4 (see RθJA values listed in thermal °C RθJA = 19°C/W, TA = 85°C 99.1 characteristics table) RθJA = 31.5°C/W, TA = 85°C 108.4 RθJA = 49.2°C/W, TA = 85°C 121.5 1394b Differential input voltage, VID Cable inputs, during data reception 200 800 mV Cable inputs, during data reception 118 260 1394a Differential input voltage, VID mV Cable inputs, during arbitration 168 265 TPB cable inputs, source power node 0.4706 2.515 1394a Common-mode input voltage, V VIC TPB cable inputs, nonsource power node 0.4706 2.015(2) Power-up reset time, tpu RESET input 2(3) ms TPA, TPB cable inputs, S100 operation ±1.08 1394a receive input jitter TPA, TPB cable inputs, S200 operation 0.5 ns TPA, TPB cable inputs, S400 operation ±0.315 Between TPA and TPB cable inputs, S100 operation ±0.8 1394a receive input skew Between TPA and TPB cable inputs, S200 operation ±0.55 ns Between TPA and TPB cable inputs, S400 operation ±0.5 (1) All typical values are at VDD = 3.3 V and TA = 25°C. (2) For a node that does not source power, see Section 4.2.2.2 in IEEE 1394a-2000. (3) Time after valid clock received at PHY XI input terminal. Copyright © 2008–2009, Texas Instruments Incorporated Submit Documentation Feedback 15 Product Folder Link(s): TSB41BA3D |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |