| поискавой системы для электроныых деталей |
|
38K2 датащи(PDF) 82 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
38K2 датащи(HTML) 82 Page - Renesas Technology Corp |
|
82 / 358 page ![]() FUNCTIONAL DESCRIPTION Rev.2.00 Oct 15, 2006 page 63 of 130 38K2 Group REJ09B0338-0200 HARDWARE HUB Related Registers The HUB related registers are shown below. Fig. 93 Structure of HUB interrupt source enable register Fig. 94 Structure of HUB interrupt source register b7 b0 DP1E DP2E b6:b2 HRWUE 0 0 – 0 – – – – HUB interrupt source enable register (HUBICON) [address 002816] Bit name Bit symbol At reset Function H/W S/W O O O O O O O O HUB downstream port 1 interrupt enable bit HUB downstream port 2 interrupt enable bit Not used HUB upstream port remote- wakeup output enable bit 0 : Interrupt disabled 1 : Interrupt enabled 0 : Interrupt disabled 1 : Interrupt enabled Write “0” when writing. “0” is read when reading. 0 : Disabled 1 : Enabled –: State remaining 00 00 0 W R b7 b0 DP1 DP2 b6:b2 HRWU – – – – 0 0 – 0 HUB interrupt source register (HUBIREQ) [address 002916] Bit name Bit symbol At reset Function H/W S/W HUB downstream port 1 interrupt bit HUB downstream port 1 interrupt bit Not used HUB upstream port remote -wakeup output enable bit This bit is set to “1” when any one of DP1 interrupt source register’s bits at least is set to “1”. This bit is cleared to “0” by clearing DP1 interrupt source register to “0016”. Writing to this bit causes no state change. This bit is set to “1” when any one of DP2 interrupt source register’s bits at least is set to “1”. This bit is cleared to “0” by clearing DP2 interrupt source register to “0016”. Writing to this bit causes no state change. Write “0” when writing. “0” is read when reading. 0 : Remote-wakeup being not output 1 : Remote-wakeup being output This bit change is not for a interrupt source. When detecting 2.5 µs or more of K-signal on a downstream port in Hub-suspended state, K-signal is output on from a upstream port and this bit is simultaneously set to “1”. “0” can be set by software, but “1” cannot be set. O O O O ✕ ✕ O O –: State remaining 0 000 0 W R |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |