303 / 499 page ![]() 16. MULTI-MASTER I2C bus INTERFACE p u o r G 9 2 / C 6 1 M page 279 8 5 4 f o 7 0 0 2 , 0 3 .r a M 2 1 . 1 . v e R 2 1 1 0 - 1 0 1 0 B 9 0 J E R 16.11 STOP Condition Generation Method When the ES0 bit in the S1D0 register is set to 1 (I2C bus interface enabled) and bits MST and TRX in the S10 register are set to 1 at the same time, set the BB flag, PIN bit and 4 low-order bits in the S10 register to 0 simultaneously, to enter STOP condition standby mode. When dummy data is written to the S00 register next, the STOP condition is generated. The STOP condition generation timing varies between standard clock mode and high-speed clock mode. See Figure 16.17 and Table 16.8. Until the BB flag in the S10 register becomes 0 (bus free) after an instruction to generate the STOP condi- tion is executed, do not write data to registers S10 and S00. Otherwise, the STOP condition waveform may not be generated correctly. If an input signal level of the SCL pin is set to low ("L") after the instruction to generate the STOP condition is executed, a signal level of the SCL pin becomes high ("H"), and the BB flag is set to 0 (bus free), the MCU outputs an "L" signal to SCL pin. In that case, the MCU can stop an "L" signal output to the SCL pin by generating the STOP condition, writing 0 to the ES0 bit in the S1D0 register (disabled), or writing 1 to the IHR bit in the S1D0 register (reset release). 16.10 START Condition Duplicate Protect Function A START condition is generated when verifying that the BB flag in the S10 register does not use buses. However, if the BB flag is set to 1 (bus busy) by the START condition which other master device generates immediately after the BB flag is verified, the START condition is suspended by the START condition dupli- cate protect function. When the START condition duplicate protect function starts, it operates as follows: •Disable the start condition standby setting If the function has already been set, first exit START condition standby mode and then set bits MST and TRX in the S10 register to 0. •Writing to the S00 register is disabled. (The START condition trigger generation is disabled) •If the START condition generation is interrupted, the AL flag in the S10 register becomes 1.(arbitration lost detection) The START condition duplicate protect function is valid between the SDA falling edge of the START condi- tion and the receive completion of the slave address. Figure16.15 shows the duration of the START condition duplicate protect function. Figure 16.15 The duration of the start condition duplicate protect function 1 clock 1 bit SCL SDA BB flag 2 bit 3 bit 2 clock 3 clock 8 bit ACK bit The duration of start condition duplicate protect 8 clock ACK clock |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |